• 热门标签

当前位置: 主页 > 航空资料 > 飞行资料 >

时间:2010-06-12 21:59来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

High explosive warhead with PD fuzing with a MK 66 motor.
High explosive warhead with remote set fuzing with a MK 66 motor.
Illumination warhead with remote set fuzing with a MK 66 motor.
Smoke warhead with remote set fuzing with a MK 66 motor.
Multi-purpose submunitions warhead with remote set fuzing with a MK 66 motor.
Not implemented.
Indicates the functional rounds remaining in inventory by zone location.
4 - 2 4
TM 1-1520-238-10
Table 4-7. Pilot Aerial Rocket Control Panel/Indicator Functions - continued
Control/
Indicator Switch Function
ZONE SEL Pressing the appropriate ZONE SEL switch arms the selected zone. When any one
zone is selected all other zones displaying the same zone inventory will be
automatically armed and visually indicated by illumination of the appropriate
ZONE SEL switches. Any currently selected (armed) zones which are different
from the ZONE SEL switch pressed will automatically be deselected (de-armed).
PEN-M Permits the pilot to select tree height of burst detonation (5 meter increments),
superquick detonation, or bunker penetration prior to detonation.
45
40
35 Canopy height in meters.
30
25 Enables rocket to penetrate canopy of
20 foliage or building and
15 detonate at a more
10 effective point.
BNK Bunker penetration - To defeat bunkers (logs and dirt) up to 3 meters thick.
SQ Superquick - detonates when fuze makes contact with any object.
QTY Selects the quantity of rockets to be fired.
ALL Sustained or continuous fire of all rockets in zones selected.
24 24 rockets to be fired
12 12 rockets to be fired.
8 8 rockets to be fired.
4 4 rockets to be fired.
2 2 rockets to be fired.
1 1 rocket to be fired.
- No rockets to be fired
Change 3 4-25
TM 1-1520-238-10
Table 4-7. Pilot Aerial Rocket Control Panel/Indicator Functions - continued
Control/
Indicator Switch Function
NOTE
The RNG-KM thumbwheel selectors on the rocket panel are the pilo t manual
range entry for ALL armament the pilot may select. Automatic range calculations
are based on the pilot LOS and radar altitude; a flat earth model.
RNG-KM Left Thumbwheel selector
Numerals Selects multiples of 1000 meters.
A Signals for automatic range calculation to be executed. During rocket
engagements time to function fuzing data is passed by the FCC to the ARCS.
Right Thumbwheel selector
Numerals Selects multiples of 100 meters.
4.20.2 Pilot Missile Control Panel. The pilot missile
control panel, placarded MSL (fig 4-11), is located in
the pilot left console (fig 2-11). The function of each control
is described in table 4-8.
Figure 4-11. Pilot Missile Control Panel
Table 4-8. Pilot Missile Control Panel Control/Indicator Functions
Control/
Indicator Switch Function
LOAL OFF Disables Lock-On- After-Launch mode and defaults to Lock-On- Before-Launch
(LOBL) missile launch mode.
DIR Direct fire LOAL launch trajectory.
LO, HI Indirect fire LOAL launch trajectories.
LSR CODE This is the CHAN SEL switch and used to command the missile subsystem to
accept and validate the mode, code and quantity of missiles selected. The selection
of UPPER or LOWER tells the missiles subsystem which coded missiles to
establish as the priority channel, by default, the other coded missiles are the
alternate channel.
4-26 Change 3
WARNING
TM 1-1520-238-10
4.20.3 Pilot Fire Control Panel. The pilot fire control protection is provided by the FC AC and FC DC circuit
panel, placarded FIRE CONTROL (fig 4-12), is lo- breakers located on the pilot overhead circuit breaker
cated in the lower left quadrant of the pilot vertical panel. The function of each control is described in table
instrument panel (fig 2-9) and receives power from the 4-9.
No. 1 essential bus and the No. 3 essential dc bus;
Figure 4-12. Pilot Fire Control Panel
Table 4-9. Pilot Fire Control Panel/Indicator Functions
Control/
Indicator Position Function
With CPG PLT/GND switch in ORIDE and pilots MASTER switch OFF, pilots SAFE/ARM
lights will not indicate a SAFE or ARMED condition of the CPG ARM/SAFE switch. Further,
with CPG SIGHT SELECT switch in NVS, HAD is not present to display weapons
status messages.
MASTER OFF
SAFE
ARM
Disables all weapon control and power to weapons.
Enables SAFE power to the pilot weapons select switches and provides safe power
to the CPG ARM switch. A green SAFE light indicates a valid safe condition.
Enables ARM power to all weapon firing circuits and provides ARM power to the
CPG ARM switch. An amber ARM light indicates a valid arm condition.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:阿帕奇攻击直升机操作手册1(144)