• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2010-06-06 21:55来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

- Select AGENT 2 pushbutton.
When the AGENT 2 pushbutton is pressed, the second
fire bottle is discharged in the engine compartment
and the DISCH light comes on.
- Select ENG MASTER 1 lever to OFF.
When the second engine is shut down, if the APU is not
running the ECAM displays are lost.
If the APU is running, it must be shut down.
TMUFIR605-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2
Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 32
ALL
ENGINE FIRE PROTECTION - SYSTEM OPERATION IN CASE OF ENGINE FIRE ON GROUND
TMUFIR605-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3
Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 33
ALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR605 LEVEL 3
EFFECTIVITY 26-12-00 Page 4
Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 34
ALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION:
PRECAUTIONS
CONTENTS:
General
Fire Bottle
Discharge Cartridge
TMUFIAZ02 LEVEL 3
EFFECTIVITY 26-12-00 Page 1
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 35
ALL
ENGINE FIRE PROTECTION: PRECAUTIONS
GENERAL
Specific precautions must be taken during removal or
installation of a fire extinguishing bottle and a
discharge cartridge.
FIRE BOTTLE
WARNING: The fire bottle cartridges are explosive.
Remove them before working on the bottle.
Protective caps must be installed during
bottle removal/installation to prevent
damage to discharge diaphragm which could
result in injury to personnel.
DISCHARGE CARTRIDGE
WARNING: Before power is supplied to the aircraft make
certain that electrical circuits upon which
work is in progress are isolated.
WARNING: Cartridges are class "C" explosives and must
be handled or stored by authorized personnel
or disposed of by an approved method.
When cartridge electrical connectors are
disconnected, the cartridge electrical pins
must be shunted with a protective shunt which
is provided by the manufacturer. A shunt plug
or shorting clip, will prevent bottle
discharge which could cause injury to
maintenance personnel.
The cartridge installed must be of the same
make as the fire bottle and correspond to the
specification indicated in the Maintenance
Manual.
TMUFIAZ02-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 36
ALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION COMPONENTS
CONTENTS:
Fire Detection Unit (FDU)
Fire Bottles
Fire Detectors
TMUFIRJ08 LEVEL 3
EFFECTIVITY 26-12-00 Page 1
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 37
ALL
ENGINE FIRE PROTECTION COMPONENTS
SAFETY PRECAUTIONS:
WARNING:
- Cartridges are explosive, remove them before working
on the bottle. Protective caps must be installed during
bottle removal/installation to prevent damage to the
discharge diaphragm which could result in injury to
personnel.
- Before power is supplied to the aircraft make certain
that electrical circuits upon which work is in progress
are isolated.
Dischage cartridges are class "c" explosives and must
be handled/stored by authorized personnel or disposed
of by an approved method.
When cartridge electrical connectors are disconnected
the cartridge electrical pins must be shunted with a
protective shunt which is provided by the
manufacturer.A shunt plug or shorting clip will prevent
bottle discharge which could injury to maintenace
personnel.
The cartridge installed must be of the same make as
the bottle and correspond to the specification
indicated in the Maintenance Manual.
TMUFIRJ08-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 38
ALL
THIS PAGE INTENTIONNALLY LEFT BLANK
 