曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
continuous repetitive chime sounds, the MASTER WARNING
flashes and the AIR conditioning page appears with the
smoke message on the ECAM.
Note that the FWD & AFT ventilation and heating systems
are optional.
On A320 and A319 only:
The FWD & AFT cargo fire protection systems are
optional and independent.
The cargo fire extinguishing option requires the cargo
smoke detection option.
TMUFIAD04-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 144
ALL
CARGO SMOKE DETECTION WARNING
TMUFIAD04-P01 LEVEL 3
EFFECTIVITY 26-16-00 Page 3
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 145
ALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAD04 LEVEL 3
EFFECTIVITY 26-16-00 Page 4
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 146
ALL
26 - FIRE PROTECTION
26-16-00 CARGO SMOKE PROCEDURE
CONTENTS:
Cargo Smoke Procedure
TMUFIAE01 LEVEL 3
EFFECTIVITY 26-16-00 Page 1
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 147
ALL
CARGO SMOKE PROCEDURE
CARGO SMOKE PROCEDURE
Note that the ventilation, the heating and the smoke
protection systems are optional and independent for
each compartment.
When cargo smoke is detected (bulk smoke is shown as
an example), the continuous repetitive chime sounds,
the MASTER WARN flashes and the SMOKE light on the
CARGO SMOKE panel comes on.
The isolation valves of the cargo compartment are
automatically closed and the ISOL VALVE FAULT light
on the CARGO HEAT panel comes on.
- Select the AFT ISOL VALVE pushbutton.
(Available only if AFT ventilation system is
installed)
When the AFT ISOL VALVE pushbutton is set to OFF, the
isolation valves closure is confirmed.
- Select the DISCH pusbutton for the AFT cargo
compartment.
When the DISCH pushbutton is pressed, the fire bottle
is discharged into the cargo compartment. As the bottle
pressure is released, the pressure switch provides the
DISCH light activation.
With the smoke extinguished, all warnings disappear
except the DISCH lights which remains illuminated.
For information, note that in case of cargo smoke
warning on ground you should never discharge the
on-board extinguishing bottle. Make a visual
inspection of the cargo compartment and use portable
extinguishers if fire is confirmed.
TMUFIAE01-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 148
ALL
CARGO AND LAVATORY FIRE PROTECTION - CARGO SMOKE PROCEDURE
TMUFIAE01-P01 LEVEL 3
EFFECTIVITY 26-16-00 Page 3
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 149
ALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAE01 LEVEL 3
EFFECTIVITY 26-16-00 Page 4
Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 150
ALL
26 - FIRE PROTECTION
26-16-00 CARGO AND LAVATORY FIRE
PROTECTION - LAVATORY SMOKE
DETECTION WARNINGS
CONTENTS:
Lavatory Smoke Warnings
TMUFIAF19 LEVEL 3
EFFECTIVITY 26-16-00 Page 1
Jan 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 151
ALL
CARGO AND LAVATORY FIRE PROTECTION - LAVATORY SMOKE DETECTION WARNINGS
LAVATORY SMOKE WARNINGS
When lavatory smoke is detected the alarms are
transmitted to the cockpit and the cabin.
In the cockpit, the Continuous Repetitive Chime sounds,
the MASTER WARNING flashes and a message appears on
the engine warning display.
Note that an option disables lavatory warnings in the
cockpit.
In the cabin, the continuous high-low chime sounds in
all attendant loudspeakers and the red SMOKE LAV P/B
light on the Forward Attendant Panel flashes. The red
light on all Attendant Indication Panels flashes and
the affected lavatory is shown in clear wording.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
ATA 26 FIRE PROTECTION(20)