• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2010-06-06 21:55来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

EFFECTIVITY Page 98
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - EXTINGUISHING
TMUFIRR01-P02 LEVEL 3
EFFECTIVITY 26-13-00 Page 3
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 99
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - APU FIRE PUSH
TMUFIRR01-P03 LEVEL 3
EFFECTIVITY 26-13-00 Page 4
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 100
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - DISCH
TMUFIRR01-P04 LEVEL 3
EFFECTIVITY 26-13-00 Page 5
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 101
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - AUTO EXTINGUISHING
TMUFIRR01-P05 LEVEL 3
EFFECTIVITY 26-13-00 Page 6
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 102
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - FIRE DETECTION
TMUFIRR01-P06 LEVEL 3
EFFECTIVITY 26-13-00 Page 7
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 103
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - TEST
TMUFIRR01-P07 LEVEL 3
EFFECTIVITY 26-13-00 Page 8
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 104
ALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - RESET
TMUFIRR01-P08 LEVEL 3
EFFECTIVITY 26-13-00 Page 9
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 105
ALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRR01 LEVEL 3
EFFECTIVITY 26-13-00 Page 10
May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 106
ALL
26 - FIRE PROTECTION
26-15-00 SYSTEM PRESENTATION
CONTENTS:
Smoke Detector
Avionic Equipment Ventilation Computer (AEVC)
Gen 1 Line P/B
Blower and Extract P/B
Self Examination
TMUFIRO01 LEVEL 1
EFFECTIVITY 26-15-00 Page 1
Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 107
ALL
SYSTEM PRESENTATION
SMOKE DETECTOR
The avionics compartment smoke detection is provided
by a smoke detector installed on the air extraction
duct of the avionics ventilation system. In case of
smoke detection, the smoke detector sends signals to
the Flight Warning Computer, the local warnings and
the Avionics Equipment Ventilation Computer. The smoke
detector is of the ionization type.
AVIONIC EQUIPMENT VENTILATION COMPUTER (AEVC)
The Avionic Equipment Ventilation Computer controls
the avionics ventilation system, monitors the smoke
detector condition, and allows the detector to be
tested by the Centralized Fault Display System. The
Avionics Equipment Ventilation Computer (AEVC) checks
the smoke detector when a test is initiated from the
Centralized Fault Display Interface Unit (CFDIU).
GEN 1 LINE PUSHBUTTON
The smoke detector activates the GEN 1 LINE SMOKE light
on the EMER ELEC PWR panel.
BLOWER AND EXTRACT PUSHBUTTON
The smoke detector activates the BLOWER FAULT and
EXTRACT FAULT lights on the ventilation panel.
TMUFIRO01-T01 LEVEL 1
EFFECTIVITY 26-15-00 Page 2
Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 108
ALL
SYSTEM PRESENTATION
TMUFIRO01-P01 LEVEL 1
EFFECTIVITY 26-15-00 Page 3
Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 26 FIRE PROTECTION
UF94200
EFFECTIVITY Page 109
ALL
SELF EXAMINATION
How can the avionics smoke detector be tested?
A - Permanently by the AEVC.
B - By a dedicated TEST pushbutton.
C - By a manual test from the CFDS.
Which warning lights are triggered in case of an
avionic smoke detection?
A - GEN 1 LINE SMOKE light.
B - BLOWER FAULT.
C - GEN 1 LINE SMOKE and BLOWER and EXTRACT
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:ATA 26 FIRE PROTECTION(14)