ducts. AC powered with 3 phases. A thermal switch
isolates the electrical supply in case of stator temp
of 140°C (284°F). A relay signals malfunction to the
ECAM and CFDS via the zone controller.
TMUTEMS0A-T11 LEVEL 3
EFFECTIVITY 21-60-00 Page 22
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 132
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - RECIRCULATION FAN
TMUTEMS0A-P11 LEVEL 3
EFFECTIVITY 21-60-00 Page 23
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 133
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
RECIRCULATION CHECK VALVES
IDENTIFICATION
FIN: 4020HM, 4021HM
LOCATION
ZONE: 137, 138
COMPONENT DESCRIPTION
They are installed downstream of each cabin
recirculation fan. They prevent back flow to the FWD
cargo compartment if case of fan failure.
TMUTEMS0A-T12 LEVEL 3
EFFECTIVITY 21-60-00 Page 24
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 134
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - RECIRCULATION CHECK VALVES
TMUTEMS0A-P12 LEVEL 3
EFFECTIVITY 21-60-00 Page 25
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 135
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
TOILET AND GALLEY EXTRACTION FAN
IDENTIFICATION
FIN: 1HU
LOCATION
ZONE: 172
COMPONENT DESCRIPTION
The fan (AC powered with 3 phases) extracts toilet and
galley air to the outflow valve area. A thermal switch
isolates the electrical supply in case of stator
temperature of 134°C (273°F) A relay signals malfunction
to the ECAM and CFDS via the zone controller.
TMUTEMS0A-T13 LEVEL 3
EFFECTIVITY 21-60-00 Page 26
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 136
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - TOILET AND GALLEY EXTRACTION FAN
TMUTEMS0A-P13 LEVEL 3
EFFECTIVITY 21-60-00 Page 27
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 137
ALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUTEMS0A LEVEL 3
EFFECTIVITY 21-60-00 Page 28
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 138
ALL
21 - AIR CONDITIONING
21-55-00 ZONE TEMPERATURE CONTROL -
EMERGENCY RAM AIR INLET
COMPONENTS
CONTENTS:
Emergency Ram Air Inlet Actuator
Emergency Check Valve
TMUTEMQ01 LEVEL 1
EFFECTIVITY 21-55-00 Page 1
Sep 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 139
ALL
ZONE TEMPERATURE CONTROL - EMERGENCY RAM AIR INLET COMPONENTS
EMERGENCY RAM AIR INLET ACTUATOR
IDENTIFICATION
FIN: 7HZ
LOCATION
ZONE: 191
COMPONENT DESCRIPTION
It consists of a 28 VDC motor with 2 travel limit
switches and 2 limit switches for ECAM indication.
EMERGENCY RAM AIR INLET CHECK VALVE
IDENTIFICATION
FIN: 4022HL
LOCATION
ZONE: 137
COMPONENT DESCRIPTION
The check valve is installed in line with the air
delivery duct, between the ram air inlet and the mixer
unit. It prevents mixer unit back flow.
TMUTEMQ01-T01 LEVEL 1
EFFECTIVITY 21-55-00 Page 2
Sep 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 140
ALL
TMUTEMQ01-P01 LEVEL 1
ZONE TEMPERATURE CONTROL - EMERGENCY RAM AIR INLET COMPONENTS
EFFECTIVITY 21-55-00 Page 3
Sep 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 141
ALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUTEMQ01 LEVEL 1
EFFECTIVITY 21-55-00 Page 4
Sep 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 142
ALL
21 - AIR CONDITIONING
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
ATA 21 AIR CONDITIONING(21)