• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2010-05-01 10:28来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Failure analysis yes yes
BITE yes yes
BITE storage and transmission
to CFDS no yes
ECAM indications yes yes
DATA handling yes yes
Ovht detection and indication yes yes
ATA 36 bleed valve status no yes
ATA 30 anti-ice failures and
status no yes
Fan monitoring yes no
TMUTEMS0A-T01 LEVEL 3
EFFECTIVITY 21-60-00 Page 2
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 112
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - ZONE CONTROLLER
TMUTEMS0A-P01 LEVEL 3
EFFECTIVITY 21-60-00 Page 3
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 113
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
MIXER UNIT FLAP ROTARY ACTUATOR
IDENTIFICATION
FIN: 20HB
LOCATION
ZONE: 137
COMPONENT DESCRIPTION
Operated by a 28 VDC motor
Mixer unit flap normally closed.
It opens when Pack 1 is selected OFF to ensure
sufficient airflow to the cockpit.
TMUTEMS0A-T02 LEVEL 3
EFFECTIVITY 21-60-00 Page 4
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 114
ALL
TMUTEMS0A-P02 LEVEL 3
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - MIXER UNIT FLAP ROTARY ACTUATOR
EFFECTIVITY 21-60-00 Page 5
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 115
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
MIXER TEMPERATURE SENSORS
IDENTIFICATION
FIN: 24HK, 25HK
LOCATION
ZONE: 137, 137
COMPONENT DESCRIPTION
There are two mixer temperature sensors one installed
on each side of the mixer unit. They send data to the
zone controller.
TMUTEMS0A-T03 LEVEL 3
EFFECTIVITY 21-60-00 Page 6
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 116
ALL
TMUTEMS0A-P03 LEVEL 3
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - MIXER TEMPERATURE SENSORS
EFFECTIVITY 21-60-00 Page 7
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 117
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
TRIM AIR CHECK VALVE
IDENTIFICATION
FIN: 18HM, 19HM
LOCATION
ZONE: 191, 192
COMPONENT DESCRIPTION
They are installed upstream of the hot pressure
regulating valve. One is installed in each trim air
duct from the bleed system. They prevent back-flow.
TMUTEMS0A-T04 LEVEL 3
EFFECTIVITY 21-60-00 Page 8
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 118
ALL
TMUTEMS0A-P04 LEVEL 3
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - TRIM AIR CHECK VALVE
EFFECTIVITY 21-60-00 Page 9
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 119
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
TRIM AIR PRESSURE REGULATING VALVE (PRV)
IDENTIFICATION
FIN: 14HK
LOCATION
ZONE: 137
COMPONENT DESCRIPTION
Electrically controlled and pneumatically actuated.
One microswitch for indication (ECAM and FAULT light).
Two solenoids:
- one for control: energized = valve open,
- one for reduced airflow: energized = press
reduction.
TMUTEMS0A-T05 LEVEL 3
EFFECTIVITY 21-60-00 Page 10
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 120
ALL
TMUTEMS0A-P05 LEVEL 3
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS - TRIM AIR PRESSURE REGULATING VALVE (PRV)
EFFECTIVITY 21-60-00 Page 11
Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 21 AIR CONDITIONING
UF94200
EFFECTIVITY Page 121
ALL
ZONE TEMPERATURE CONTROL - ZONE COMPONENTS
HOT AIR PRESSURE SWITCH
IDENTIFICATION
FIN: 26HK
LOCATION
ZONE: 137
COMPONENT DESCRIPTION
It signals pressure regulating valve outlet
overpressure of 6.5 psi (0.45 bar) for ECAM display.
TMUTEMS0A-T06 LEVEL 3
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:ATA 21 AIR CONDITIONING(19)