• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-11-01 11:19来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

to 15 lb-in. maximum.

(5)Refer to Volume 1, 20-60-00 for details on the application of corrosion
inhibiting compound.

(6)Apply BMS 3-23 to the interior of the door, giving special attention to
structural seams. Do not apply to drain valve or other operational mech-anism.

(7)
Restore door to normal.

 

B.
Frequency of Application. Periodically inspect the door structure and con-dition of the corrosion inhibitor and leveling compound. Reapply corrosion
inhibiting compound as required. Local areas where gouges and scratches have
occurred should be treated at the first opportunity consistent with the
maintenance schedule.

 

Volume 2-757

52-40-02

Page 1
OCT 01/00

CORROSION PREVENTIONMANUAL
FORWARD ACCESS DOOR


LEAF SPRING TYPE DRAIN VALVE

PLUNGER TYPE DRAIN VALVE

DETAIL I
Forward Access Door
Figure 1


Volume 2-757

52-40-02
Page 2 OCT 01/00
CORROSION PREVENTIONMANUAL
ELECTRICAL/ELECTRONICS ACCESS DOOR


1. General

A. The electrical/electronics access door has a corrosion protective finish
that consists of chemical finish (Alodine) on clad aluminum parts, anodize
surface treatment on non-clad aluminum parts, a coat of BMS 10-11, type I,
primer and a coat of BMS 10-11, type II, enamel. Faying surfaces of dissim-ilar metals and parts attached to the door skin are fay sealed with BMS 5-95
sealant. All areas of possible moisture accumulation are drained or filled
with BMS 5-125 leveling compound. The exterior of the door is unfinished

during production unless otherwise requested by the operator.

B. Areas of possible corrosion are the internal structure of the door, connec-tion points and mechanisms.

C. Corrosion  can also occur on the frame structure under the latch fitting,
which mates with the latch pin on the door. Refer to 53-30-01 for further
information.

2.  Corrosion Prevention

A. Make periodic inspections as described in Volume 1, 20-20-00 to ensure that
the protective finishes provided during manufacture remain intact.

(1) Gain access to interior structure of the door.


(2)Clean out drains and drain paths. Check condition of leveling compound
(Ref Component Maintenance Manual, 52-48-15).

(3)Check that drain valve is free to open and close.


CAUTION:  EXCESSIVE TIGHTENING OF PLUNGER TYPE DRAIN VALVE WILL CAUSE VALVE
FLANGE TO CRACK OR BREAK.

(4) If required, remove plunger type drain valve from outside of door, clean
out obstructions and reinstall valve until flange contacts skin. Tighten
to 15 lb-in. maximum.

(5)Refer  to Volume 1, 20-60-00 for details on the application of corrosion
inhibiting compound.

(6)Apply corrosion  inhibiting compound to the interior of the door, giving
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 防腐手册 CORROSION PREVENTION MANUAL(19)