EFFECTIVITY
AIRPLANES WITH
DRAIN MASTS
F89855
Passenger Water System Equipment Location 5C8
38-11-0 Figure 1 (Sheet 1) May 01/00
Page 2
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
EFFECTIVITY
AIRPLANES WITHOUT
DRAIN MASTS
F90255 F90138
5C8 Passenger Water System Equipment Location
May 01/00 Figure 1 (Sheet 2) 38-11-0
Page 3
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
Passenger Water System Components Location 5C8
38-11-0 Figure 1 (Sheet 3) Jun 20/85
Page 4
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
5C8 Passenger Water System Schematic
May 01/00 Figure 2 38-11-0
Page 5
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
5. Water System Valves
A. Fill and Overflow Valve (Fig. 1)
(1) The fill and overflow valve controls filling of the passenger water system. The valve is a four-port machined body with a rotary core. The rotary core is spring-loaded to ensure positive seating and prevent leakage. The valve is operated by a handle attached to the rotary core by a short stem. It is a 2-way valve with an OPEN and a CLOSED position. During flight the valve must be in the CLOSED position. The OPEN position permits filling of the water tank. The fill and overflow valve is located just above the water service panel. Plumbing from the fill and overflow valve is connected to the water service panel located on the airplane fuselage below the aft entry door. The panel contains a fill connection and an overflow outlet.
B. Drain Valves
(1)
Lavatory Drain Valves (Fig. 3)
(a)
Each lavatory is provided with a drain valve which controls potable water drainage of lavatory compartment plumbing. The valve has 3 positions: OFF, DRAIN and ON. In the OFF position all lines are completely closed. In the DRAIN position all lines are completely open. In the ON (normal) position, the water inlet and outlet lines are open and the drain line is closed. The valve is accessible in the lower part of the lavatory sink cabinet below the water heater.
(b)
On airplanes with forward lavatory, a secondary drain valve may be installed to prevent in flight accidental drainage. The existing 3-way drain valve is designated the primary drain valve. The secondary drain valve is a 2-way valve with an OPEN and a CLOSED position. The secondary valve is accessible in the lower part of the lavatory sink cabinet.