∞∞78-31-00∞∞∞∞∞∞∞∞∞∞Page 287
E May 01/05E E F EEFF : ALL E
R E ECES
F 『
E C F M E
E E
E 56 E
E E
- set the engine 1 throttle control lever to idle position,
- do a check of the wiring continuity between the static
relay (3EG1), the SEC1 (1CE1) and the SEC2 (1CE2).
k_ If the wiring is correct:
- make sure that there is no ground at pin AB/15E on the
SEC1 (1CE1) and the SEC2 (1CE2) (Ref. ASM 78-37/01).
- look for any FCDC or radio altimeter failure (on the Post
Flight Report (PFR)) causing SEC output malfunction (TSM
chapter 27).
l_ If no external failure to the SECs is found:
- replace successively the SEC-1 (1CE1) then the SEC-2
(1CE2) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM
TASK 27-94-34-400-001).
(3) If thrust reverser operation (deploy and stow) was normal during aircraft operation and during the test but the test gives the maintenance message HCU, TRSOV, HYD or HCU (TRPV), HYD:
- replace the HCU pressure switch (4102KS) (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041).
(a) If the fault continues:
- replace the HCU (4101KS1) (Ref. AMM TASK 78-31-51-000-042) and (Ref. AMM TASK 78-31-51-400-042).
B. Do the test given in Para. 3.B.
(1) No additional maintenance action is required if the fault is not confirmed.
(2) Repeat the fault isolation procedure if the fault continues.
F 『 EEFF : ALL E ∞∞78-31-00∞∞∞∞∞∞∞∞∞∞Page 288
E E May 01/05 ERE
ECES
F 『
E C F M E
E E
E 56 E
E E
TASK 78-31-00-810-856
Failure of the Thrust Reverser Hydraulic Isolation Valve in the Closed Position on Engine 2
1. Possible Causes
_______________
- STATIC RELAY-THRUST REVERSER LOCKING CTL, ENG2 (3EG2)
- RELAY-THRUST REVERSER LOCKING POWER, ENG2 (2EG2)
- VALVE-THRUST REVERSER HYDRAULIC ISOLATION, ENG2 (50EG2)
- HCU-THRUST REV (4101KS)
- C/B-SAFETY CIRCUIT BREAKER OPEN (1EG2)
- C/B-ENGINE/ENG2/OIL/PRESS (2EN2)
- SEC-1 (1CE1)
- SEC-3 (1CE3)
- HCU pressure switch (4102KS)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
AMM 78-31-00-710-042 Operational Test of the Thrust Reverser System
AMM 78-31-16-000-041 Removal of the Hydraulic Control Unit Pressure Switch
(4102KS) AMM 78-31-16-400-041 Installation of the Hydraulic Control Unit Pressure
Switch (4102KS) AMM 78-31-51-000-042 Removal of the Hydraulic Control Unit AMM 78-31-51-400-042 Installation of the Hydraulic Control Unit AMM 78-37-51-000-001 Removal of the Thrust Reverser Hydraulic Isolation
Valve
AMM 78-37-51-400-001 Installation of the Thrust Reverser Hydraulic
Isolation Valve
ASM 78-37/01
AWM 78-36-03
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU ENG2/REV/LOCK 1EG2 N45 121VU ENGINE/ENG2/OIL/PRESS 2EN2 N42
F 『 EEFF : ALL E ∞∞78-31-00∞∞∞∞∞∞∞∞∞∞Page 289
E E May 01/05 ERE ECES
F 『
E C F M E
E E
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 EXHAUST(42)