 (1) If the fault continues:

 (a) Do a check and repair the wiring if necessary between:
 - RELAY (6LP) connector A/17 and PB SW (13WR) connector A/7

 - RELAY (6LP) connector A/33 and CB (1WR)

 - RELAY (6LP) connector A/31 and GND

 - RELAY (15WR) connector A/X1 and CB (1WR)

 - RELAY (15WR) connector A/X2 and GND,
 (Ref. ASM 35-23/01).

 


 (2) If the fault continues:


 - Do the operational test of the annunciator light test system (Ref. AMM TASK 33-14-00-710-001).
 (a) If the test gives a different maintenance message:
 - Do the trouble shooting procedure related to the maintenance message.
 C. If the FAULT legend on the pushbutton switch OXYGEN/TMR RESET, which is installed on the panel 50VU, comes on and goes off after pushing the OXYGEN/MASK MAN ON pushbutton switch:
 - Do a check of the RELAY-TIME DELAY (15WR) and replace it if necessary (Ref. ASM 35-23/01).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞35-23-00∞∞∞∞∞∞∞∞∞∞Page 208
 201-299, 301-399, Aug 01/05 CES


 (1) If the fault continues:

 (a) Do a check and repair the wiring if necessary between:
 - RELAY (6LP) connector A/17 and PB SW (13WR) connector A/7

 - RELAY (6LP) connector A/33 and CB (1WR)

 - RELAY (6LP) connector A/31 and GND

 - RELAY (15WR) connector A/X1 and CB (1WR)

 - RELAY (15WR) connector A/X2 and GND, (Ref. ASM 35-23/01).

 

 (2) If the fault continues:


 - Do the operational test of the annunciator light test system (Ref. AMM TASK 33-14-00-710-001).
 (a) If the test gives a different maintenance message:
 - Do the trouble shooting procedure related to the maintenance message.
 D. Do the test as given in the Para. 3.A.
 5. Close-up
________
 A. Put the aircraft back to its initial configuration.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞35-23-00∞∞∞∞∞∞∞∞∞∞Page 209
 201-299, 301-399, Aug 01/05 CES

 TASK 35-23-00-810-804


 Power Supply Line Fault
 1. Possible Causes
_______________
 - RELAY-PWR SPLY (10WR)

 - wiring

 - RELAY-TIME DELAY (25WR)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 35-23-00-710-001 Operational Check of Manual Mask Release ASM 35-23/01
 3. Fault Confirmation
__________________
 A. Do the operational test of the manual mask release (Ref. AMM TASK 35-23-00-710-001).
 4. Fault Isolation
_______________
 A. If one set of masks (approx. half of the installed masks) drops after approx. 6 seconds:
 - Do a check of the RELAY-PWR SPLY (10WR) and replace it if necessary (Ref. ASM 35-23/01).
 (1) If the fault continues:
 (a) Do a check and repair the wiring if necessary between:
 - RELAY (10WR) connector A/D1 and CB (4WR)

 - RELAY (10WR) connector A/D2 RELAY (25WR) connector A/A2

 - RELAY (10WR) connector A/C1 and CB (5WR)

 - RELAY (10WR) connector A/C2 RELAY (25WR) connector A/A1

 - RELAY (10WR) connector A/B1 and CB (6WR)

 - RELAY (10WR) connector A/B2 RELAY (25WR) connector A/B1

 - RELAY (10WR) connector A/A1 and CB (7WR)

 - RELAY (10WR) connector A/A2 RELAY (25WR) connector A/B2, (Ref. ASM 35-23/01).


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞35-23-00∞∞∞∞∞∞∞∞∞∞Page 210
 201-299, 301-399, Aug 01/05 CES


 B. If one set of masks (approx. half of the installed masks) does not fall during the test:
 - Do a check of the RELAY-PWR SPLY (10WR) and replace it if necessary (Ref. ASM 35-23/01).
 (1) If the fault continues:

 - Do a check of the RELAY-TIME DELAY (25WR) and replace it if necessary (Ref. ASM 35-23/01).

 (2) If the fault continues:


 (a) Do a check and repair the wiring if necessary between:
 - RELAY (10WR) connector A/D1 and CB (4WR)
 