- STOWAGE BOX-OXY MASK, F/O (10RN2)
- STOWAGE BOX-OXY MASK, 3RD OCCPNT (10RN3)
- BOX ASSY-STOWAGE, 4TH OCCPNT (5774HM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 35-12-41-000-001 Removal of the Oxygen-Mask Stowage-Box
AMM 35-12-41-400-001 Installation of the Oxygen-Mask Stowage-Box
AMM 35-12-41-710-001 Operational Test of the Full Face/Quick Donning
R Oxygen Masks (5757HM,5758HM,5759HM,5760HM)
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the full-face/quick-donning oxygen masks: (Ref. AMM TASK 35-12-41-710-001).
4. Fault Isolation
_______________
A. If during the operational test:
(1) There is no oxygen at the Captain mask stowage box:
- replace the STOWAGE BOX-OXY MASK, CAPT (10RN1) (Ref. AMM TASK 35-12-41-000-001) and (Ref. AMM TASK 35-12-41-400-001).
(2) There is no oxygen at the F/O mask stowage box:
- replace the STOWAGE BOX-OXY MASK, F/O (10RN2) (Ref. AMM TASK 35-12-41-000-001) and (Ref. AMM TASK 35-12-41-400-001).
(3) There is no oxygen at the Third Occupant mask stowage box:
- replace the STOWAGE BOX-OXY MASK, 3RD OCCPNT (10RN3) (Ref. AMM TASK 35-12-41-000-001) and (Ref. AMM TASK 35-12-41-400-001).
(4) There is no oxygen at the Fourth Occupant mask stowage box:
- replace the BOX ASSY-STOWAGE, 4TH OCCPNT (5774HM) (Ref. AMM TASK 35-12-41-000-001) and (Ref. AMM TASK 35-12-41-400-001).
B. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞35-10-00∞∞∞∞∞∞∞∞∞∞Page 217
Nov 01/02 CES
TASK 35-10-00-810-811
Crew Oxygen Indication less than 400PSI on the DOOR/OXY page
1. Possible Causes
_______________
- CYLINDER-OXYGEN STORAGE (5750HM)
- XMTR/PRESS REG-OXY (4HT)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power AMM 31-60-00-860-001 EIS Start Procedure AMM 31-60-00-860-002 EIS Stop Procedure AMM 35-10-00-040-001 OXY High Pressure Indication-Direct Reading. AMM 35-11-41-000-001 Removal of the Crew Oxygen-Storage Cylinder (5750HM) AMM 35-11-41-400-001 Installation of the Crew Oxygen-Storage Cylinder
(5750HM) AMM 35-13-15-000-001 Removal of the Oxygen Pressure Regulator/Transmitter (4HT) AMM 35-13-15-400-001 Installation of the Oxygen Pressure Regulator/Transmitter (4HT)
3. Fault Confirmation
__________________
A. Job Set Up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU OXYGEN/CREW/OXY/SPLY 1HT HA01
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞35-10-00∞∞∞∞∞∞∞∞∞∞Page 218
Feb 01/98 CES
C. Test
(1) On the ECAM control panel:
- push the DOOR key to get the DOOR/OXY page.
(2) Make sure that the OXY pressure indication is less than 400PSI.
(3) Do an OXY high-pressure indication direct reading (Ref. AMM TASK 35-10-00-040-001).
4. Fault Isolation
_______________
A. If during the check of the pressure of the crew cylinder, the value is:
(1) The same as the value on the SD, on the DOOR/OXY page:
- replace the CYLINDER-OXYGEN STORAGE (5750HM) (Ref. AMM TASK 35-11-41-000-001) and (Ref. AMM TASK 35-11-41-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 氧气 OXYGEN(14)