• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 22:27来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 AMM 25-35-25-400-001 Installation of the Hot-Cup
 ASM 25-31/01
 ASM 25-32/01
 ASM 25-33/01

 3. Fault Confirmation
__________________

 A. Do the operational test of the hot-cup (Ref. AMM TASK 25-35-00-710-020).
 4. Fault Isolation
_______________

 A. If the hot-cup does not operate during the test:
 - Replace the hot-cup (Ref. AMM TASK 25-35-25-000-001) and (Ref. AMM TASK 25-35-25-400-001).
 (1) If the fault continues:

 - Do a check and if necessary repair the wiring between the related galley control panel and the electrical connector of the hot-cup.

 - Do a check and if necessary repair the related CB at the galley control panel and if installed the related relays or switches (Ref. ASM 25-31/01) (Ref. ASM 25-32/01) (Ref. ASM 25-33/01).

 

 (2) If the fault continues:


 - Do a check and if necessary repair the wiring of the galley (Ref. TASK 24-56-00-810-801).
 一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一 R EFF : 001-049, 051-099, 101-105, ∞∞25-35-00∞∞∞∞∞∞∞∞∞∞Page 207
 May 01/05 CES

 

 B. Do the test given in Para. 3.A

 


R **ON A/C 001-049, 101-105,
 TASK 25-35-00-810-810

 Hot-Jug does not operate
 1. Possible Causes
_______________

 - hot-jug

 - wiring


 - electrical connector of the hot-jug

 - related CB


 - related relays or switches


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-56-00-810-801 Galley Supply Fault
 AMM 25-35-00-710-021 Operational Test of the Hot-Jug
 AMM 25-35-25-000-002 Removal of the Hot-Jug
 AMM 25-35-25-400-002 Installation of the Hot-Jug
 ASM 25-31/01
 ASM 25-32/01
 ASM 25-33/01

 3. Fault Confirmation
__________________

 A. Do the operational test of the hot-jug (Ref. AMM TASK 25-35-00-710-021)
 4. Fault Isolation
_______________

 A. If the hot-jug does not operate during the test:
 - Replace the hot-jug (Ref. AMM TASK 25-35-25-000-002) and (Ref. AMM TASK 25-35-25-400-002).
 (1) If the fault continues:

 - Do a check and if necessary repair the wiring between the related galley control panel and the electrical connector of the hot-jug.

 - Do a check and if necessary repair the related CB at the galley control panel and if installed the related relays or switches (Ref. ASM 25-31/01) (Ref. ASM 25-32/01) (Ref. ASM 25-33/01).

 

 (2) If the fault continues:


 - Do a check and if necessary repair the wiring of the galley (Ref. TASK 24-56-00-810-801).
 一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一 R EFF : 001-049, 101-105, ∞∞25-35-00∞∞∞∞∞∞∞∞∞∞Page 209
 May 01/05 CES

 

 B. Do the test given in Para. 3.A

 


R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
 TASK 25-35-00-810-812

 Water-Heater/Boiler does not operate
 1. Possible Causes
_______________

 - water-heater

 - wiring


 - electrical connector of the water-heater

 - related CB


 - related relays or switches


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-56-00-810-801 Galley Supply Fault
 AMM 25-35-00-710-023 Operational Test of the Water-Heater/Boiler
 AMM 25-35-27-000-001 Removal of the Water Boiler/Heater
 AMM 25-35-27-400-001 Installation of the Water Boiler/Heater
 ASM 25-31/01
 ASM 25-32/01
 ASM 25-33/01

 3. Fault Confirmation
__________________

 A. Do the operational test of the water-heater (Ref. AMM TASK 25-35-00-710-023).
 4. Fault Isolation
_______________

 A. If the water-heater does not operate during the test:
 - Replace the water-heater (Ref. AMM TASK 25-35-27-000-001) and (Ref. AMM TASK 25-35-27-400-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual EQUIPMENT/FURNISHINGS(19)