3. Fault Confirmation
__________________
A. Do the operational test of the hot-cup (Ref. AMM TASK 25-35-00-710-020).
4. Fault Isolation
_______________
A. If the hot-cup does not operate during the test:
- Replace the hot-cup (Ref. AMM TASK 25-35-25-000-001) and (Ref. AMM TASK 25-35-25-400-001).
(1) If the fault continues:
- Do a check and if necessary repair the wiring between the related galley control panel and the electrical connector of the hot-cup.
- Do a check and if necessary repair the related CB at the galley control panel and if installed the related relays or switches (Ref. ASM 25-31/01) (Ref. ASM 25-32/01) (Ref. ASM 25-33/01).
(2) If the fault continues:
- Do a check and if necessary repair the wiring of the galley (Ref. TASK 24-56-00-810-801).
一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一 R EFF : 001-049, 051-099, 101-105, ∞∞25-35-00∞∞∞∞∞∞∞∞∞∞Page 207
May 01/05 CES
B. Do the test given in Para. 3.A
R **ON A/C 001-049, 101-105,
TASK 25-35-00-810-810
Hot-Jug does not operate
1. Possible Causes
_______________
- hot-jug
- wiring
- electrical connector of the hot-jug
- related CB
- related relays or switches
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-56-00-810-801 Galley Supply Fault
AMM 25-35-00-710-021 Operational Test of the Hot-Jug
AMM 25-35-25-000-002 Removal of the Hot-Jug
AMM 25-35-25-400-002 Installation of the Hot-Jug
ASM 25-31/01
ASM 25-32/01
ASM 25-33/01
3. Fault Confirmation
__________________
A. Do the operational test of the hot-jug (Ref. AMM TASK 25-35-00-710-021)
4. Fault Isolation
_______________
A. If the hot-jug does not operate during the test:
- Replace the hot-jug (Ref. AMM TASK 25-35-25-000-002) and (Ref. AMM TASK 25-35-25-400-002).
(1) If the fault continues:
- Do a check and if necessary repair the wiring between the related galley control panel and the electrical connector of the hot-jug.
- Do a check and if necessary repair the related CB at the galley control panel and if installed the related relays or switches (Ref. ASM 25-31/01) (Ref. ASM 25-32/01) (Ref. ASM 25-33/01).
(2) If the fault continues:
- Do a check and if necessary repair the wiring of the galley (Ref. TASK 24-56-00-810-801).
一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一 R EFF : 001-049, 101-105, ∞∞25-35-00∞∞∞∞∞∞∞∞∞∞Page 209
May 01/05 CES
B. Do the test given in Para. 3.A
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
TASK 25-35-00-810-812
Water-Heater/Boiler does not operate
1. Possible Causes
_______________
- water-heater
- wiring
- electrical connector of the water-heater
- related CB
- related relays or switches
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-56-00-810-801 Galley Supply Fault
AMM 25-35-00-710-023 Operational Test of the Water-Heater/Boiler
AMM 25-35-27-000-001 Removal of the Water Boiler/Heater
AMM 25-35-27-400-001 Installation of the Water Boiler/Heater
ASM 25-31/01
ASM 25-32/01
ASM 25-33/01
3. Fault Confirmation
__________________
A. Do the operational test of the water-heater (Ref. AMM TASK 25-35-00-710-023).
4. Fault Isolation
_______________
A. If the water-heater does not operate during the test:
- Replace the water-heater (Ref. AMM TASK 25-35-27-000-001) and (Ref. AMM TASK 25-35-27-400-001).