- related relays or switches
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-56-00-810-801 Galley Supply Fault AMM 25-35-00-710-015 Operational Test of the Oven AMM 25-35-19-000-001 Removal of the Oven AMM 25-35-19-400-001 Installation of the Oven ASM 25-31/01 ASM 25-32/01 ASM 25-33/01
3. Fault Confirmation
__________________
A. Do the operational test of the oven (Ref. AMM TASK 25-35-00-710-015).
4. Fault Isolation
_______________
A. If the oven does not operate during the test:
- Replace the oven (Ref. AMM TASK 25-35-19-000-001) and (Ref. AMM TASK 25-35-19-400-001).
(1) If the fault continues:
- Do a check and if necessary repair the wiring between the related galley control panel and the electrical connector of the oven.
- Do a check and if necessary repair the related CB at the galley control panel and if installed the related relays or switches (Ref. ASM 25-31/01) (Ref. ASM 25-32/01) (Ref. ASM 25-33/01).
(2) If the fault continues:
- Do a check and if necessary repair the wiring of the galley (Ref. TASK 24-56-00-810-801).
一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一 EFF : ALL ∞∞25-35-00∞∞∞∞∞∞∞∞∞∞Page 203
May 01/05 CES
B. Do the test given in Para. 3.A
R **ON A/C 051-099,
R TASK 25-35-00-810-806
R Steam-Oven does not operate
R 1. Possible Causes_______________
R - steam-oven
R - wiring
R - electrical connector of the steam-oven
R - related CB
R - related relays or switches
R 2. Job Set-up Information______________________
R A. Referenced Information
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 24-56-00-810-801 Galley Supply Fault
R AMM 25-35-00-710-016 Operational Test of the Steam Oven
R AMM 25-35-19-000-003 Removal of the Steam-Oven
R AMM 25-35-19-400-003 Installation of the Steam-Oven
R ASM 25-31/01
R ASM 25-32/01
R ASM 25-33/01
R 3. Fault Confirmation__________________
R A. Do the operational test of the steam-oven (Ref. AMM TASK 25-35-00-710-R 016).
R 4. Fault Isolation
_______________
R A. If the steam-oven does not operate during the test:
R - Replace the steam-oven (Ref. AMM TASK 25-35-19-000-003) and (Ref. AMM
R TASK 25-35-19-400-003).
R (1) If the fault continues:
R - Do a check and if necessary repair the wiring between the related
R galley control panel and the electrical connector of the
R steam-oven.
R - Do a check and if necessary repair the related CB at the galley
R control panel and if installed the related relays or switches (Ref.
R ASM 25-31/01) (Ref. ASM 25-32/01) (Ref. ASM 25-33/01).
一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一 R EFF : 051-099, ∞∞25-35-00∞∞∞∞∞∞∞∞∞∞Page 205
May 01/05 CES
R (2) If the fault continues:
R - Do a check and if necessary repair the wiring of the galley
R (Ref. TASK 24-56-00-810-801).
R B. Do the test given in Para. 3.A
R **ON A/C 001-049, 051-099, 101-105,
TASK 25-35-00-810-809
Hot-Cup does not operate
1. Possible Causes
_______________
- hot-cup
- wiring
- electrical connector of the hot-cup
- related CB
- related relays or switches
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-56-00-810-801 Galley Supply Fault
AMM 25-35-00-710-020 Operational Test of the Hot-Cup
AMM 25-35-25-000-001 Removal of the Hot-Cup
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual EQUIPMENT/FURNISHINGS(18)