the DCBPCU will automatically attempt to transfer the bus to another power
source.
4. Controls and Indications:
A. Circuit Breakers:
Circuit breakers controlling the DC bus distribution system are shown in
bold print in the tables that follow. Circuit breakers receiving power from the
controlling circuit breaker are shown immediately following that circuit
breaker.
Example: The WARN LTS PWR #1 circuit breaker receives power from the
PILOT 1 section of the Essential DC bus. Thus the PILOT 1 circuit breaker
is the controlling circuit breaker.
OPERATING MANUAL
PRODUCTION AIRCRAFT SYSTEMS 2A-24-00
Page 57
May 30/02
Revision 7
Essential DC Bus Pilot 1 CBs
Table 4
Circuit Breaker Name CB Panel Location (PDB Section)
PILOT 1 PDB DC ESS
WARN LTS PWR #1 P F-1
WARN LTS PWR #2 P F-2
WARN LTS PWR #3 P F-3
WARN LTS PWR #4 P F-4
WARN LTS PWR #5 P F-5
WARN LTS PWR #6 P G-1
WARN LTS PWR #7 P G-2
WHEEL WELL LTS P F-6
L FIRE DET LOOP B P G-6
L SEC LOCK P G-7
L T/REV CONTROL P I-7
ENGINE START P K-6
L #1 IGN P I-8
R #1 IGN P I-9
APU FIRE EXT P I-10
AFT EMERG BATT P I-13
FWD IMPACT P J-13
MAIN PUMP CONT PO A-1
L FUEL S/O PO A-2
L FUELING S/O PO A-3
FUEL X FLOW V PO D-2
FUEL PUMP IND PO A-4
EPMP SW PWR #1 PO A-5
BATT CHGR CONT PO A-6
BATT AMMETER PO A-7
AC EXT PWR PO A-8
L BLEED AIR PO A-10
R BLEED AIR IND PO C-12
L AIR COND PO C-13
CKPT/CABIN TEMP IND PO A-11
CABIN PRESS IND PO A-12
BOT A/C LT GND OPER
(No ASC 10) P E-6
AIR INLET DOOR PO C-11
SGL PACK PO C-14
ESS DC VM P D-13
CKPT TEMP CONT PO B-13
AFT EMER BAT P I-13
ANTISKID OUTBD
(1183 & 1214 & Subs) PO A-2
ELWS 1 PO A-9
OPERATING MANUAL
2A-24-00 PRODUCTION AIRCRAFT SYSTEMS
Page 58
May 30/02
Revision 7
Essential DC Bus Pilot 2 CBs
Table 5
Circuit Breaker Name CB Panel Location (PDB Section)
PILOT 2 PDB DC ESS
#2 STANDBY WARN PWR P B-1
R CKPT ANN LTS PWR P B-2
PED ANN LTS PWR P D-2
ANN LTS CONT STBY P B-3
WARN LTS PWR #8 P G-3
WARN LTS PWR #10 P G-5
WARN LTS PWR #11 P H-3
WARN LTS PWR #12 P H-4
WARN LTS PWR #13 P H-5
WARN LTS PWR #14 P I-4
WARN LTS PWR #15 P I-5
WARN LTS TEST P J-5
SPD BRAKE/FLAP ALARM P D-4
FLAP/STAB WARN P D-3
FIRE BELL P B-4
DOME LT P B-6
UTILITY LTS P D-9
R FIRE DET LOOP B P H-6
R SEC LOCK P H-7
R ENG O’HT P H-9
FIRE EXT SHOT #2 P H-8
APU START P H-10
STBY PWR CONT P H-12
FWD EMER BATT P H-13
AFT IMPACT P K-13
R FUEL S/O PO B-2
R FUELING S/O PO B-3
FUEL INTERTANK V PO B-4
FUEL LOW LEVEL PO B-1
EPMP SW PWR #2 PO B-5
BATT CHGR FAIL ANN PO B-6
BACKUP CONT PWR PO B-7
R BLEED AIR PO B-10
L BLEED AIR IND PO B-12
CABIN PRESS 28V P B-11
OVHD ANN LTS PWR #4 P C-4
OVHD ANN LTS PWR #5 P C-5
R AIR COND PO D-13
OVHD PNL PRI
(1040 & Subs) P B-9
CABIN TEMP CONT PO D-14
OPERATING MANUAL
PRODUCTION AIRCRAFT SYSTEMS 2A-24-00
Page 59
May 30/02
Revision 7
Circuit Breaker Name CB Panel Location (PDB Section)
PILOT 2 PDB DC ESS
FWD EMER BATT P H-13
ANTISKID INBD PO B-2
ELWS 2 PO B-9
Essential DC Bus Pilot 3 CBs
Table 6
Circuit Breaker Name CB Panel Location (PDB Section)
PILOT 3 PDB DC ESS
#1 STANDBY WARN PWR P A-1
L CKPT ANN LTS PWR P A-2
ANN LTS CONT MAIN P A-3
OVHD ANN LTS PWR #1 P C-1
OVHD ANN LTS PWR #2 P C-2
OVHD ANN LTS PWR #3 P C-3
LDG WARN HORN P E-4
TONE WARN #1 P A-5
APU FIRE WARN P A-4
FLOOD LITES OVERRIDE P A-6
L FIRE DET LOOP A P I-6
R FIRE DET LOOP A P J-6
L T/R EMER STOW P L-7
R T/R EMER STOW P K-7
ENGINE OILER P L-9
L ENG O’HT P G-9
L #2 IGN P J-8
R #2 IGN P J-9
FIRE EXT SHOT #1 P G-8
APU PWR #3 P L-10
R T/REV CONTROL P J-7
L FLT PNL/GSHLD
(1040 & Subs) P A-7
OPERATING MANUAL
2A-24-00 PRODUCTION AIRCRAFT SYSTEMS
Page 60
May 30/02
Revision 7
Essential DC Bus Copilot 1 CBs
Table 7
Circuit Breaker Name CB Panel Location (PDB Section)
COPILOT 1 PDB DC ESS
BUS CONT #1 CP K-2
BUS CONT #3 CP M-2
SYM GEN #1 CP K-3
DISPLAY UNIT #1 CP E-6
IRU #1 DC SEC CP J-5
E DDRMI #1 CP H-5
L PITOT HT CONT CP L-12
STBY PITOT HT CONT CP L-13
AOA PRB HTR #1 CP L-14
FWC #1 CP A-13
DAU #1A CP A-14
MANUAL FLAP CONT CPO A-1