¦ AIRCRAFT: ¦ REVISION NO: 5 ¦ PAGE: ¦
¦ G-IV ¦ ¦ ¦
¦ ¦ DATE: 10/11/2001 ¦ 24-6 ¦
¦ --------------------------------------------------------------------------- ¦
¦ 1. ¦ 2. NUMBER INSTALLED ¦
¦ SYSTEM & ¦ -------------------------------------------- ¦
¦ SEQUENCE ITEM ¦ ¦ 3. NUMBER REQUIRED FOR DISPATCH ¦
¦ NUMBERS ¦ ¦ --------------------------------------- ¦
¦ ------------------------- ¦ ¦ ¦ 4. REMARKS OR EXCEPTIONS ¦
¦ 24 ELECTRICAL POWER ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ 12. Master Power C ¦ 3 ¦ 2 ¦ (O)One may be inoperative provided ¦
¦ Switch Lights ¦ ¦ ¦ associated AC loadmeter and ¦
¦ (Left, Right, AUX) ¦ ¦ ¦ voltmeter are operative and ¦
¦ ¦ ¦ ¦ selected for monitoring. ¦
¦ ¦ ¦ ¦ ¦
¦ 13. APU Alternator OFF D ¦ 1 ¦ 0 ¦ ¦
¦ Warning System ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ 14. Battery D ¦ 1 ¦ 0 ¦ ¦
¦ *** Temperature ¦ ¦ ¦ ¦
¦ Indicating System ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ 15. Standby Electrical C ¦ 1 ¦ 0 ¦ ¦
¦ System ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ 16. Converter Cooling C ¦ 10 ¦ 9 ¦ (M)One may be inoperative provided: ¦
¦ Fans ¦ ¦ ¦ a) Normal operation of ¦
¦ ¦ ¦ ¦ remaining fans is verified ¦
¦ ¦ ¦ ¦ before each departure, and ¦
¦ ¦ ¦ ¦ b) Airplane is operated in ¦
¦ ¦ ¦ ¦ accordance with AFM. ¦
¦ ¦ ¦ ¦ ¦
¦ 17. External Power D ¦ 1 ¦ 0 ¦ ¦
¦ Systems ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ 18. Electrical Load D ¦ 1 ¦ 0 ¦ ¦
¦ *** Warning System ¦ ¦ ¦ ¦
¦ (ELWS) ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
¦ U.S. DEPARTMENT OF TRANSPORTATION ¦
¦ ¦
¦ MASTER MINIMUM EQUIPMENT LIST ¦
¦ FEDERAL AVIATION ADMINISTRATION ¦
¦ --------------------------------------------------------------------------- ¦
¦ AIRCRAFT: ¦ REVISION NO: 5 ¦ PAGE: ¦
¦ G-IV ¦ ¦ ¦
¦ ¦ DATE: 10/11/2001 ¦ 24-7 ¦
¦ --------------------------------------------------------------------------- ¦
¦ 1. ¦ 2. NUMBER INSTALLED ¦
¦ SYSTEM & ¦ -------------------------------------------- ¦
¦ SEQUENCE ITEM ¦ ¦ 3. NUMBER REQUIRED FOR DISPATCH ¦
¦ NUMBERS ¦ ¦ --------------------------------------- ¦
¦ ------------------------- ¦ ¦ ¦ 4. REMARKS OR EXCEPTIONS ¦
¦ 24 ELECTRICAL POWER ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ 19. APU Alternator C ¦ 1 ¦ 0 ¦ (M)(O)May be inoperative provided: ¦
¦ Overheat Warning ¦ ¦ ¦ a) APU is not operated, ¦
 