• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2010-05-01 10:13来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

UF94200
EFFECTIVITY Page 302
ALL
23 - COMMUNICATIONS
23-73-00 CIDS - EVACUATION SIGNALLING
CONTENTS:
General
Activation From the Cockpit
Activation From the Cabin
TMUCI2203 LEVEL 3
EFFECTIVITY 23-73-00 Page 1
May 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 303
ALL
CIDS - EVACUATION SIGNALLING
GENERAL
The EVAC Signalling System is used to provide aural
and visual signals in the cabin and in the cockpit for
evacuation, following a request from the flight crew
or attendants should an emergency condition happen.
The system can be controlled either from the cockpit
or from the cabin.
In the cockpit, a control panel and a horn for aural
indications are installed
The control panel contains:
- A COMMAND guarded pushbutton to start the
signalling or for a complete reset with two
labels.
- EVAC: which flashes red when the system is
actived.
- ON: which comes on white when the pushbutton
is pressed in.
- A HORN SHUT OFF pushbutton to silence the horn
in the cockpit.
- A two positions switch:
- CAPT AND PURS: Allows the system to be
triggered either from the cockpit or the cabin.
- CAPT: The system can only be triggered from
the cockpit.
In the cabin, the system can be controlled from the
FAP or AAP. The system configuration is defined by
each customer.
The following Keys are used for this purpose:
- RESET: cancels the evacuation tone in the
corresponding door area attendant
loudspeakers.
- EVAC: Signals the EVAC signalling activation
(EVAC Alert Signal).
- CMD: It is used to activate the EVAC
signalling and to display a EVAC COMMAND
Indication.
TMUCI2203-T01 LEVEL 3
EFFECTIVITY 23-73-00 Page 2
May 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 304
ALL
CIDS - EVACUATION SIGNALLING
TMUCI2203-P01 LEVEL 3
EFFECTIVITY 23-73-00 Page 3
May 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 305
ALL
CIDS - EVACUATION SIGNALLING
ACTIVATION FROM THE COCKPIT.
The system can be actived by using the COMMAND guarded
pushbutton on the EVAC Panel 21VU on the Overhead
Panel.
The following indications will happen:
- The EVAC indicator light in the COMMAND
pushbutton switch flashes.
- The ON indicator light in the COMMAND
pushbutton switch comes on.
- The EVAC horn gives an intermittend signal.
On the Forward Attendant Panel (FAP) and on the AAP:
- The EVAC indicator lights flash.
From the attendant loudspeakers:
- The EVAC tone is heard as an intermittent
signal.
On all the attendant indication panels "EVACUATION
ALERT" message is displayed associated with flashing
red light (optional).
In this configuration, one of the following actions
can be performed at a time:
- By using the EVAC COMMAND pushbutton, all
messages are cancelled in the cockpit and in
the cabin.
- By using the EVAC HORN SHUT OFF, the EVAC horn
is silenced.
- By using, on the FAP, the RESET pushbutton,
The EVAC tone stops from the forward attendant
loudspeakers.
- By using, on the AAP, the RESET pushbutton,
the EVAC tone stops on the relevant
attendant loudspeakers.
TMUCI2203-T01 LEVEL 3
EFFECTIVITY 23-73-00 Page 4
May 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 306
ALL
CIDS - EVACUATION SIGNALLING
ACTIVATION FROM THE CABIN.
1-THE EVAC CAPT PURS/CAPT SWITCH TO THE CAPT PURS
POSITION.
The system can be activated from any of the attendant
stations by using the FAP/AAP CMD Key.
When the CMD Key is pressed, the following will happen:
- The EVAC indicator light in the COMMAND
pushbutton switch, on the overhead panel,
flashes.
- The EVAC horn, in the cockpit broadcasts an
intermittent signal.
- The CMD indicator light in the EVAC CMD Key
comes on, on the corresponding panel.
- The EVAC indicator light comes on, on all
attendant panels.
- The EVAC tone is heard as an intermittent
signal, from all attendant loudspeakers.
- The "EVACUATION ALERT" message is displayed on
all the Attendant Indication Panels associated
with flashing red light (optional).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:ATA 23 COMMUNICATIONS(45)