EFFECTIVITY Page 227
ALL
FORWARD ATTENDANT PANEL PRESENTATION
GENERAL
The Forward Attendant Panel (FAP) is located at the
purser’s station. With the FAP the various cabin
systems can be controlled and monitored. It is
connected to the directors and to the type B DEU
(300RH1).
The FAP is composed of four parts:
- the air conditioning panel,
- the light panel,
- the audio panel,
- the water and miscellaneous panel.
AIR CONDITIONING
Optionally, in this part of the FAP, the forward and
aft cabin temperatures are indicated.
CABIN LIGHTING
The cabin light panel comprises control pushbuttons
for the various cabin lights.
There are controls for the entrance areas and the
different cabin sections.
The BRT, DIM1 and DIM2 pushbuttons respectively switch
on the lights at 100%, 50% and 10% intensity.
In addition, a power switch provides the power for the
lavatory lights, attendant work lights and the
passenger reading lights.
There are also controls for the window lights and the
ceiling lights.
All pushbuttons, except for MAIN ON and MAIN OFF, have
integral lights for visual indication of the activated
functions.
AUDIO PANEL
The audio panel allows centralized control of the
passenger entertainment, boarding music and
prerecorded announcements.
TMUCI2J03-T01 LEVEL 1
EFFECTIVITY 23-73-12 Page 2
Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 228
ALL
FORWARD ATTENDANT PANEL PRESENTATION
TMUCI2J03-P01 LEVEL 1
EFFECTIVITY 23-73-12 Page 3
Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 229
ALL
FORWARD ATTENDANT PANEL PRESENTATION
WATER AND MISCELLANEOUS PANEL
EMERGENCY LIGHT PUSHBUTTON
EMER LIGHT is a red guarded pushbutton, with an
integral light, used to switch the emergency lighting
system ON and OFF.
LAVATORY SMOKE LIGHT
The LAV SMOKE light is used to warn of lavatory smoke.
A command from the Smoke Detection Control Unit (SDCU)
resets the indication only when the smoke has gone.
RESET MEMBRANE SWITCH
When the RESET membrane switch is pressed, in case of
lavatory smoke warning, it resets only the aural and
visual indication in the passenger compartment,
without affecting the LAV SMOKE indication on the FAP.
EVAC
The EVAC indicator light is controlled by a discrete
input.
EVAC COMD
The EVAC COMD membrane switch, switches on the
evacuation system. The integral light in the membrane
switch comes on.
Pushing the membrane switch a second time switches off
the evacuation system and the integral light.
CHIME INHIB
As an option, this membrane switch enables the
inhibition of a passenger to cabin attendant call
chime.
CALL RESET
As an option, the CALL RESET membrane switch enables
a central reset of passenger calls for all zones.
CABIN READY
As an option, this membrane switch is used to indicate
the "CABIN READY FOR TAKE OFF" status in the cockpit.
PANEL LIGHT TEST
The PNL LIGHT TEST membrane switch is used to switch
on all the FAP lights (bulb check).
CIDS CAUT
The integral light indicates CIDS CAUTIONS.
The CIDS CAUT light is resettable in flight, but comes
on again on the ground when the landing gear is down
and locked. The light cannot be reset on the ground.
When a CIDS CAUT occurs, the respective failure message
is displayed on the Programming and Test Panel (PTP).
TMUCI2J03-T01 LEVEL 1
EFFECTIVITY 23-73-12 Page 4
Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 230
ALL
23 - COMMUNICATIONS
23-73-13 AFT ATTENDANT PANEL PRESENTATION
CONTENTS:
General
Functions
TMUCI2K03 LEVEL 1
EFFECTIVITY 23-73-13 Page 1
May 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 23 COMMUNICATIONS
UF94200
EFFECTIVITY Page 231
ALL
AFT ATTENDANT PANEL PRESENTATION
GENERAL
From the Aft Attendant Panel (AAP), the cabin
attendants can control various cabin systems in the
same way as on the Forward Attendant Panel.
The location and the front face layout vary with the
airline options.
The Aft Attendant Panels (AAPs) are connected to type
B DEUs.
FUNCTIONS
The basic panel comprises:
 