Hydromechanical Unit 9 Functions:
1.
Fuel Pumping (high pressure Ng driven vane pump).
2.
Fuel flow Metering (main metering valve controlled by the pilot, HMU, and ECU).
3.
Collective pitch compensation through LDS (incr/decr fuel flow via collective movement).
4.
Acceleration/Deceleration fuel flow limiting (limits metering valve movement rate).
5.
Ng limiting and Ng shutdown (max. Ng at 103%, shutdown at 110%).
6.
Variable Geometry positioning (IGV, variable vanes, and AISBV).
7.
Torque motor to trim Ng governor (ECU/HMU interface, pilot override through ECU lockout).
8.
PAS override allowing manual control with ECU inoperative (ECU lockout).
9.
Open Vapor Vent for fuel system priming (PCL in lockout position opens a HMU case vent, allows pilot to purge fuel system using prime boost, or submerged boost pump).
Ng Limiting- Ng limiting can be a function of Ng governing. The HMU mechanically computes and sets the maximum Ng speed IAW the T2 sensor input, or a physical limitation in which the Ng speed is "Max Fuel Flow limited", the resultant Ng speed with metering valve full open. The type of limiting that is in effect depends on the T2 (engine inlet temperature). Under warm climatic conditions higher Ng speeds are allowed with the maximum Ng limited to 103 % Ng (the fuel flow limited). In warm conditions, TGT limiting will most likely limit the Ng prior to Ng limiting. In extreme cold conditions, less Ng speed is allowed. The Ng limiting (Ng governing) may be entered prior to the TGT limiting. The Ng speed - T2 charts can be found in TM 1-2840-248-23 (Engine, Aircraft Turboshaft Models T700).
ECU inputs: TGT LIMITING, Np GOVERNING, and LOAD SHARE. ECUfeedback : fromLVDT inHMUto stabilize torque motor amplifier,failure of LVDT causes oscillation. malfunction.
Power Control Lever
Sets/Limits maximumpower