EFFECTIVITY
ALL CFM56-5B ENGINES FOR A319-A320-A321
CFMI PROPRIETARY INFORMATION CFDS MESSAGE
INTERROGATION
FAULT DETECTION
& ANNUNCIATION Page 32
Nov 02
CFM56-5B TRAINING MANUAL
CTC-231-081-00 THRUST REVERSER TEST
EFFECTIVITY
ALL CFM56-5B ENGINES FOR A319-A320-A321
CFMI PROPRIETARY INFORMATION CFDS MESSAGE
INTERROGATION
FAULT DETECTION
& ANNUNCIATION Page 33
Nov 02
CFM56-5B TRAINING MANUAL
CENTRALIZED FAULT DISPLAY SYSTEM (CFDS). ENGINE SYSTEMS - ECU.
FADEC test.
The FADEC test is divided into two parts. If starter air is available at the beginning of the test, a motoring test is performed. Otherwise, a non-motoring test is performed.
The non-motoring test will complete automatically in about two minutes. After the operator has pressed the line select key to start the test, a screen appears prompting the operator to place the mode selector switch to ‘NORM’ and the master lever to ‘ON’. When the conditions are met, a ‘TEST ACTIVE’ screen is displayed.
When the test is complete, a display reports that a non-motoring test was performed and prompts the operator to either press a key to display the test results, or return to the main menu.
If a fault is detected, the fault report page contains the identity of the 3 most likely failed LRU’s for the fault. A maximum of 3 faults per page are displayed with a maximum of 12 faults recorded.
If starter air is supplied, the engine is dry cranked and the various actuators and valves (except FMV, HPSOV and FRV valves) are commanded to move to certain
positions. The test will complete automatically in less than one minute.
As in the non-motoring test, after the operator has pressed the line select key to start the test, a screen appears prompting the operator to place the mode selector switch to ‘NORM’ and the master lever to ‘ON’. When the conditions are met, a ‘TEST ACTIVE’ screen is displayed.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn