EFFECTIVITY
ALL CFM56-5B ENGINES FOR A319-A320-A321
CFMI PROPRIETARY INFORMATION FAULT DETECTION
FAULT DETECTION
& ANNUNCIATION Page 26
Nov 02
CFM56-5B TRAINING MANUAL
CTC-231-030-00 CURRENT DRIVER WRAPAROUND TESTS
EFFECTIVITY
ALL CFM56-5B ENGINES FOR A319-A320-A321
CFMI PROPRIETARY INFORMATION FAULT DETECTION
FAULT DETECTION
& ANNUNCIATION Page 27
Nov 02
CFM56-5B TRAINING MANUAL
OUTPUTS
Wraparound fault detection.
Possible causes.
Example 1 : Short circuit to ground.
If there is a short circuit to ground, the current flows back to the ECU, through the ground path.
The ECU detects that i1 is not equal to i2 and generates a fault message.
Example 2 : Open circuit.
If there is an open circuit, the ECU generates a current that is unable to loop back to the ECU.
Therefore, i1 and i2 equals zero in all conditions and the ECU generates a fault message.
EFFECTIVITY
ALL CFM56-5B ENGINES FOR A319-A320-A321
CFMI PROPRIETARY INFORMATION FAULT DETECTION
FAULT DETECTION
& ANNUNCIATION Page 28
Nov 02
CFM56-5B TRAINING MANUAL
SHORT CIRCUIT TO GROUND
TORQUE MOTOR / SOLENOID
SHORT CIRCUIT TO GROUND : i1 = i2
OPEN CIRCUIT : i1 AND i2 = 0
CTC-231-031-00 WRAPAROUND FAULT DETECTION
EFFECTIVITY
ALL CFM56-5B ENGINES FOR A319-A320-A321
CFMI PROPRIETARY INFORMATION FAULT DETECTION
FAULT DETECTION
& ANNUNCIATION Page 29
Nov 02
CFM56-5B TRAINING MANUAL
OUTPUTS
Wraparound fault detection.