• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-29 11:49来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

CAUTION:  DO NOT LET OIL GET ON THE APU OR OTHER COMPONENTS. IMMEDIATELY CLEAN THE OIL WHEN IT FALLS ON THEM. OIL CAN CAUSE DAMAGE TO PAINT AND RUBBER.
CAUTION:  DO NOT MIX TYPES OR BRANDS OF OIL WHEN YOU ADD OR REPLACE THE OIL IN THE APU. INCORRECT OILS CAN CAUSE DAMAGE TO THE APU.
EFFECTIVITY BEJ ALL  49-00-00 
Page 32 
D633W101-BEJ  May 05/2003 

 

AUXILIARY POWER SYSTEM -APU ACCESS AND SERVICING

EFFECTIVITY BEJ ALL  49-00-00 
Page 33 
D633W101-BEJ  May 05/2003 

 

777 AIRCRAFT MAINTENANCE MANUAL

THIS PAGE IS INTENTIONALLY LEFT BLANK

49-10-00

Page 1 D633W101-BEJ Jan 05/2002
BOEING PROPRIETARY -Copyright # -Unpublished Work -See title page for details.

APU POWER PLANT -INTRODUCTION

General APU Drains
The power plant has these systems and components: The APU drains permit flammable fluid to drain from the APU.
*
Auxiliary power unit

*
APU mounts

*
APU wire harness

*
APU air inlet

*
APU drains.


Auxiliary Power Unit
The auxiliary power unit contains these major sections:
*
Accessory gearbox

*
Pneumatic load compressor

*
Gas turbine engine.


APU Mounts
The APU mounts hold the APU in the APU compartment and isolate the structure from APU vibration.
APU Wire Harness
The APU wire harness contains all the electrical wiring for the APU.
APU Air Inlet
The APU air inlet supplies the air for the APU engine and APU load compressor operation.
EFFECTIVITY BEJ ALL  49-10-00 
Page 2 
D633W101-BEJ  Sep 05/2002 

 

777 AIRCRAFT MAINTENANCE MANUAL


APU POWER PLANT -INTRODUCTION

EFFECTIVITY BEJ ALL  49-10-00 
Page 3 
D633W101-BEJ  Jan 05/2002 


APU POWER PLANT -AUXILIARY POWER UNIT

Clustered Components
Some APU components are in functional clusters to make maintenance easier. These clusters include:
*
Lube cluster

*
Fuel cluster

*
Pneumatic cluster

*
Ignition cluster.


Other Components
These are the other main APU components:
*
Air turbine starter control valve (ATSCV)

*
Fuel manifolds

*
Oil cooler

*
Data memory module (DMM)

*
Air turbine starter (ATS)

*
Electric starter motor

*
Surge duct.


EFFECTIVITY BEJ ALL  49-10-00 
Page 4 
D633W101-BEJ  Sep 05/2002 

 

777 AIRCRAFT MAINTENANCE MANUAL


APU POWER PLANT -AUXILIARY POWER UNIT

EFFECTIVITY BEJ ALL  49-10-00 
Page 5 
D633W101-BEJ  Jan 05/2002 


APU POWER PLANT -APU MOUNTS

Purpose
Three APU mounts hold the APU in its compartment. The mounts also isolate the structure from APU vibration.
Location
The two forward mounts attach to the APU firewall. The aft APU mount hangs from the upper tailcone structure.
EFFECTIVITY BEJ ALL  49-10-00 
Page 6 
D633W101-BEJ  Jan 05/2002 

 

777 AIRCRAFT MAINTENANCE MANUAL


APU POWER PLANT -APU MOUNTS

EFFECTIVITY BEJ ALL  49-10-00 
Page 7 
D633W101-BEJ  Jan 05/2002 


APU POWER PLANT -APU WIRE HARNESS

Purpose
The APU wire harness holds all the electrical wires in one assembly.
Location
The APU wire harness extends from the firewall connector to the front of the APU. From the front of the APU it goes in different directions around the APU to connect all electrical components.
Physical Description
Shielded, twisted pair conductors keep electromagnetic interference on circuits to a minimum. APU harness connectors are threaded, stainless steel, and self-locking.
Training Information Point
Wiring routing tags on the harness show pin to pin electrical continuity.
Quick release fastener cable clamps attach the APU harness to the APU.
EFFECTIVITY BEJ ALL  49-10-00 
Page 8 
D633W101-BEJ  Sep 05/2002 

 

777 AIRCRAFT MAINTENANCE MANUAL


APU POWER PLANT -APU WIRE HARNESS

EFFECTIVITY BEJ ALL  49-10-00 
Page 9 
D633W101-BEJ  Jan 05/2002 


APU POWER PLANT -AIR INLET -INTRODUCTION

Purpose
The APU air inlet supplies air to the APU for APU engine and load compressor operation, and for oil and APU compartment cooling. These are the APU air inlet components:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 机载辅助动力 Airborne Auxiliary Power(7)