777 AIRCRAFT MAINTENANCE MANUAL
AUXILIARY POWER SYSTEM -NORMAL SHUTDOWN
EFFECTIVITY BEJ 001-004 49-00-00
Page 23
D633W101-BEJ Sep 05/2003
777 AIRCRAFT MAINTENANCE MANUAL
AUXILIARY POWER SYSTEM -NORMAL SHUTDOWN
EFFECTIVITY BEJ 005-999 49-00-00
Page 24
D633W101-BEJ Sep 05/2003
AUXILIARY POWER SYSTEM -PROTECTIVE SHUTDOWNS
General
The APUC controls the automatic protective shutdown of the APU. If the APUC finds some APU conditions or faults, it sends a protective shutdown signal.
There are two modes of APU automatic shutdown protection, the attended mode and the unattended mode.
Attended Protective Shutdown
The attended mode operates when at least one engine is running or if the aircraft is in the air. These conditions will cause a protective shutdown in the attended mode:
*
APU overspeed (more than 106 percent RPM)
*
Loss of overspeed protection (loss of the two overspeed protection circuits)
*
APU compartment fire
*
APU inlet fire/load compressor reverse flow (T2 > 177C)
BEJ 001-004
* Load compressor Low flow (pressure sensors show low flow condition)
BEJ 005-999
* Load compressor Low flow (surge control valve does not follow command and pressure sensors show low flow condition)
BEJ ALL
*
APU speed droop (RPM less than 88 percent and no acceleration for 10 seconds)
*
APUC internal failure
EFFECTIVITY
BEJ ALL
*
Loss of power to the APUC
*
Air inlet door closes (air inlet door position switch indicates door closed, which occurs at 70 percent of full open position).
Unattended Protective Shutdown
The unattended mode operates when the main engines are not running and the airplane is on the ground. This mode supplies protective shutdown for all of the attended mode conditions plus these conditions:
*
Low oil pressure (less than 35 psi)
*
Loss of oil pressure signal (from both the pressure sensor and the low oil pressure switch)
*
High EGT (calculated turbine inlet temperature is above 1288C)
*
Loss of EGT signal (from both thermocouple rakes)
BEJ 005-999
* Generator scavenge filter is clogged
BEJ ALL
* High oil temperature (more than 156C).
Indication
All protective shutdowns cause the APU SHUTDOWN advisory message to show and turn on the APU fault light on the P5 overhead panel. The APU status message also shows when there is a protective shutdown. In the attended mode, these conditions cause the APU LIMIT caution message to show:
*
Low oil pressure
*
High EGT
49-00-00
Page 25 D633W101-BEJ Sep 05/2003
AUXILIARY POWER SYSTEM -PROTECTIVE SHUTDOWNS
* High oil temperature.
Training Information Point
You can attempt to restart the APU after you move the APU selector to OFF to unlatch the protective shutdown.
EFFECTIVITY BEJ ALL 49-00-00
Page 26
D633W101-BEJ May 05/2003
AUXILIARY POWER SYSTEM -PROTECTIVE SHUTDOWNS
EFFECTIVITY BEJ 001-004 49-00-00
Page 27
D633W101-BEJ Sep 05/2003
AUXILIARY POWER SYSTEM -PROTECTIVE SHUTDOWNS
EFFECTIVITY BEJ 005-999 49-00-00
Page 28
D633W101-BEJ Sep 05/2003
AUXILIARY POWER SYSTEM -INDICATIONS
General
The status display and maintenance page show APU system data.