WASTE TANK QUANTITY INDICATION -FUNCTIONAL DESCRIPTION
EFFECTIVITY BEJ ALL 38-33-00
Page 13
D633W101-BEJ Sep 05/2002
WASTE TANK QUANTITY INDICATION -OPERATION -CSCP/CACP INDICATIONS -1
General
You use the cabin system control panel (CSCP) or cabin area control panels (CACP) to control and monitor lavatory functions and waste tank levels.
Lavatory/Waste Tank Status Screen
You use the lavatory waste tank status screen to monitor the conditions of the lavatories and waste tanks.
The lavatories area of the screen shows lavatory locations and status. The area to the right of the lavatories shows the related waste tank and the amount of waste in it.
When the waste level is less than 1/4, the vertical bars are green. When the waste level is 1/4 to 3/4 full, the vertical bars are yellow. When the waste level is more than 3/4, the vertical bars are red.
When the waste tank level shows full (F), all related lavatories show INOP.
Lavatory Inoperable Control Screen
You use the lavatory inoperable control screen to show the conditions of the lavatories.
The screen shows the lavatories and assigned waste tanks. The status area of the screen shows the condition of each lavatory.
You touch OP or INOP to show that lavatory operational or inoperative. The OP and INOP selections show green.
INOP shows automatically for all lavatories with the same waste tank if the waste tank is full. FULL TANK shows in the area where OP would normally be. You cannot change this condition.
Use the up and down arrows at the right of the display to scroll the lavatory information up and down.
EFFECTIVITY BEJ ALL 38-33-00
Page 14
D633W101-BEJ Sep 05/2002
WASTE TANK QUANTITY INDICATION -OPERATION -CSCP/CACP INDICATIONS -1
EFFECTIVITY BEJ ALL 38-33-00
Page 15
D633W101-BEJ Sep 05/2002
WASTE TANK QUANTITY INDICATION -OPERATION -CSCP/CACP INDICATIONS -2
General
The waste tank full pop-up screen automatically comes on when a waste tank is full.
Touch the WASTE TANK STATUS to exit this screen and go to the waste tank status screen.
EFFECTIVITY BEJ ALL 38-33-00
Page 16
D633W101-BEJ Sep 05/2002
WASTE TANK QUANTITY INDICATION -OPERATION -CSCP/CACP INDICATIONS -2
EFFECTIVITY BEJ ALL 38-33-00
Page 17
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
38-42-00
Page 1 D633W101-BEJ Jan 05/2002
BOEING PROPRIETARY -Copyright # -Unpublished Work -See title page for details.
WATER TANK PRESSURIZATION -INTRODUCTION
Purpose
The water tank pressurization system pressurizes the potable water tanks for distribution.
General Description
Pressure for the water tanks comes from the pneumatic system or from a compressor. The air compressor supplies pressure to the tanks when pressure from the pneumatic system is not sufficient.
These components control the amount of pressure that goes to the tanks:
*
Pressure relief valve
*
Pressure limit switch
*
Pressure regulator
*
Compressor interlock switch.