• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-26 22:28来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

PFD position causes the PFD display to show on the inboard DU.
The EICAS position causes the EICAS display to show in the normal mode or the compacted engine display to show in the limited mode. The limited mode exists when only one DU is available for EICAS display and secondary engine display.
Movement of the inboard display selector from the PFD position or from the EICAS position to the NORM position (ND or MFD) causes the ND format to show on the inboard DU.
A failure of the inboard display selector causes the display format that shows to latch.
EFFECTIVITY BEJ ALL  31-61-00 
Page 98.206 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -DISPLAY FORMAT ALLOCATIONS -2

EFFECTIVITY BEJ ALL  31-61-00 
Page 98.207 
D633W101-BEJ  Sep 05/2002 


PRIMARY DISPLAY SYSTEM -AUTOMATIC DISPLAY SWITCHING

General
The PFD display on the outboard DUs and the EICAS display on the upper center DU automatically move to alternate locations when a DU failure occurs.
When only one DU shows the EICAS display, EICAS is in the limited mode. In the limited mode, only these three switches on the DSP have a function:
*
ENG switch

*
AIR switch

*
FUEL switch.


Outboard DU Failures
The PFD display automatically moves to the onside inboard location when a detected failure of the outboard DU occurs.
After the PFD display moves automatically, the inboard display selector on the display switching panel has no effect on the inboard DU.
Upper Center DU failures
The EICAS display automatically moves to the lower center DU when a detected failure of the center upper DU occurs. The lower DU then shows the compacted engine display.
The ENG switch on the DSP causes the display to change between EICAS display and compacted engine display.
The AIR switch controls the ECS data block.
The FUEL switch controls the fuel quantity and fuel imbalance display.
EFFECTIVITY BEJ ALL  31-61-00 
Page 98.208 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -AUTOMATIC DISPLAY SWITCHING

EFFECTIVITY BEJ ALL  31-61-00 
Page 98.209 
D633W101-BEJ  Sep 05/2002 


PRIMARY DISPLAY SYSTEM -PFD MANUAL SWITCHING

General
The PFD position of the inboard display selector on the display switching panel lets the operator move the PFD format to the inboard DU.
The outboard DU blanks when the selector is in the PFD position.
Return the inboard display selector to NORM (ND or MFD) to cause the PFD to show on the outboard DU and to cause the ND format to show on the inboard DU.
EFFECTIVITY BEJ ALL  31-61-00 
Page 98.210 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -PFD MANUAL SWITCHING

EFFECTIVITY BEJ ALL  31-61-00 
Page 98.211 
D633W101-BEJ  Sep 05/2002 


PRIMARY DISPLAY SYSTEM -MANUAL EICAS SWITCHING

General
The EICAS position of the inboard display selector on the display switching panel lets the operator move the EICAS display format to the inboard DU.
Both inboard DUs can show the EICAS display format at the same time. Both displays will be identical. One DU cannot show EICAS display and the other show compacted engine.
The upper center DU blanks when the inboard display selector is in the EICAS position.
Return the inboard display selector to NORM (ND or MFD) to cause the engine EICAS display to show on the upper center DU and to cause the ND format to show on the inboard DU.
EFFECTIVITY BEJ ALL  31-61-00 
Page 98.212 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -MANUAL EICAS SWITCHING

EFFECTIVITY BEJ ALL  31-61-00 
Page 98.213 
D633W101-BEJ  Sep 05/2002 


PRIMARY DISPLAY SYSTEM -MULTIPLE DU FAILURES

General
The display select panel (DSP) switches and the inboard display selectors on the display switching panel provide system redundancy when multiple DU failures occur.
The EICAS position of the inboard display selector causes the EICAS display format to show on an inboard DU.
The L INBD or R INBD switch on the DSP causes other EICAS formats to show on an inboard DU. The inboard display selector must be in the MFD position before the DSP L INBD or R INBD switch will have effect.
The L INBD or R INBD switch also has no effect if an outboard DU fails and the PFD automatically switches to an inboard DU.
EFFECTIVITY BEJ ALL  31-61-00 
Page 98.214 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -MULTIPLE DU FAILURES
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 指示和记录系统 2(62)