PREV MENU -This selection lets the operator return to MANUAL (AUTO) EVENT SELECTION page for the maintenance page that shows if they were accessed by the MANUAL (AUTO) EVENT SELECTION menu pages

*
MAIN MENU -The selection lets the operator return to the DISPLAY SELECTION menu page. This selection is available on the maintenance task maintenance page.


Training Information Point
The ATA that shows can have more than one page. These command buttons will cause the selected action on all pages of the ATA:
*
SEND

*
PRINT

*
ERASE

*
RECORD.


EFFECTIVITY BEJ ALL  31-61-00 
Page 98.126 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -INDIVIDUAL MAINTENANCE PAGE MENUS

EFFECTIVITY BEJ ALL  31-61-00 
Page 98.127 
D633W101-BEJ  Jan 05/2002 


PRIMARY DISPLAY SYSTEM -AIR CONDITIONING MAINTENANCE PAGE

General
The air conditioning maintenance page is available in these three display modes:
*
Real time

*
Manual event

*
Auto event.


Title
The title shows the display mode. The title shows as:
*
AIR CONDITIONING for the real time mode

*
AIR CONDITIONING MAN for the manual event mode

*
AIR CONDITIONING AUTO for the auto event mode.


Auto Event Message
In the real time mode, the auto event message shows for the most recent auto event in memory. If there are no auto events in memory, the message field is blank.
In the auto event mode, the message for the incident shows.
There is no message in the manual event mode.
Date and Time
In the real time mode, the date field shows the current date and universal coordinated time (UTC).
In the manual event mode and the auto event mode, the date field shows the date and UTC of the incident.
System Data
The air conditioning maintenance page shows environmental control system information. The information includes:
*
Zone temperature

*
Target temperature

*
Duct temperature

*
Trim valve position

*
Recirculation fan status

*
Trim air pressure

*
Pack outlet temperature

*
Pack flow

*
Turbine bypass valve position

*
Ram air inlet/exit positions

*
Compressor outlet temperature

*
Cabin temperature controller channel in control.


EFFECTIVITY BEJ ALL  31-61-00 
Page 98.128 
D633W101-BEJ  Sep 05/2002 

 

PRIMARY DISPLAY SYSTEM -AIR CONDITIONING MAINTENANCE PAGE

EFFECTIVITY BEJ ALL  31-61-00 
Page 98.129 
D633W101-BEJ  Jan 05/2002 


PRIMARY DISPLAY SYSTEM -ELECTRICAL MAINTENANCE PAGES

General
There are two electrical maintenance pages. They are available in these three display modes:
*
Real time

*
Manual event

*
Auto event.


Title
The titles show the display mode and page number. The titles show as:
*
ELECTRICAL PG 1/2 for the real time mode

*
ELECTRICAL PG 2/2 for the real time mode

*
ELECTRICAL MAN 1/2 for the manual event mode

*
ELECTRICAL MAN 2/2 for the manual event mode

*
ELECTRICAL AUTO 1/2 for the auto event mode

*
ELECTRICAL AUTO 2/2 for the auto event mode.


Auto Event Message
In the real time mode, the auto event message shows for the most recent auto event in memory. If there are no auto events in memory, the message field is blank. The message shows on both pages.
In the auto event mode, the message for the incident shows. The message shows on both pages.
There is no message in the manual event mode.
Date and Time
In the real time mode, the date field shows the current date and universal coordinated time (UTC).
In the manual event mode and the auto event mode, the date field shows the date and UTC of the incident.
System Data
The information on electrical maintenance page 1/2 includes:
*
AC voltage

*
AC frequency

*
AC load

*
DC voltage

*
DC amperage

*
IDG outlet/rise temperature

*
IDG oil and oil filter information

*
Fly by wire (FBW) DC system information.


The electrical maintenance page 2/2 has bus status information for the:
*
AC buses

*
AC standby bus

*
DC buses

*
DC standby bus

*
Ground service bus

*
Ground handling bus.
 