LOWER CARGO FIRE EXTINGUISHING -INTRODUCTION
EFFECTIVITY BEJ ALL 26-23-00
Page 3
D633W101-BEJ Jan 05/2002
LOWER CARGO FIRE EXTINGUISHING -INTERFACES
General
The lower cargo fire extinguishing system has these interfaces:
*
Cargo fire/engine control panel (P5)
*
Overhead panel ARINC 629 system (OPAS)
*
AIMS
*
ELMS
*
Cabin temperature controllers
*
Left and right ASCPCs
*
Left and right ECS miscellaneous cards.
Cargo Fire Extinguishing System Interfaces
These are the results when you push the FWD or AFT arm switches on the P5 panel:
*
The circuit for the forward or aft flow valve arms
*
The circuit for the two dump bottles arms
*
The switch gives OPAS a FWD or AFT ARMED signal
*
OPAS transmits the ARMED signal on the 629 buses
These are the results when you push the DISCH switch on the P5 panel:
*
The selected flow valve opens
*
The dump bottles discharge
*
The DISCH switch gives the OPAS a DISCH signal
*
OPAS transmits the DISCH signal on the 629 buses
*
The in-line pressure switch turns on the DISCH light on the P5 overhead panel
*
ELMS discharges the metered bottles after a delay
As the pressure in each bottle decreases, a pressure switch on the bottle sends a signal to the ELMS. The ELMS sends this data to the AIMS. The AIMS shows advisory and status messages to show that the bottle pressure is low.
Environmental Control System Interfaces
These are the results in the environmental control system when OPAS transmits the FWD ARMED signal:
*
Lower recirculation fans -off
*
Air conditioning packs -flow schedule 2
*
Pressurization air outflow -50 percent forward, 50 percent aft
*
Equipment cooling system -override mode
*
Galley chiller boost fan -off
*
Equipment cooling vent valve -closed.
These are the results in the environmental system when OPAS transmits the AFT ARMED signal:
*
Lower recirculation fans -off
*
Air conditioning packs -flow schedule 2
*
Pressurization air outflow -50 percent forward, 50 percent aft
*
Lav/galley vent fans -off
*
Aft cargo heat valves -closed
*
Bulk cargo vent fan -off
*
Bulk cargo heat valves -closed.
These functions change the air flow around and through the cargo compartments. This keeps the fire extinguishing agent in the cargo compartment and keeps smoke out of the passenger compartment and flight deck.
EFFECTIVITY BEJ ALL 26-23-00
Page 4
D633W101-BEJ Sep 05/2002
LOWER CARGO FIRE EXTINGUISHING -INTERFACES
EFFECTIVITY BEJ ALL 26-23-00
Page 5
D633W101-BEJ Jan 05/2002
LOWER CARGO FIRE EXTINGUISHING -COMPONENT LOCATIONS
Flight Deck
The cargo fire/engine control panel is in the flight deck on the P5 overhead panel.
Lower Forward Cargo Compartment
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 防火 Fire Protection(32)