G42862 G96448
External Pneumatic and Electrical Connections 500
71-09-100 Page 208 Figure 202 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. May 15/67
504 Engine Control Stand and Start Switch Panel
May 15/79 Figure 203 71-09-100
Page 209
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
B. Check Engine Ignition
(1)
Perform engine operation preparations in par. 3.
(2)
Pull (open) START VALVES circuit breaker on P6 panel.
(3)
On airplanes with 4 position rotary start switch, with start lever in CUTOFF, rotate engine start switch (forward overhead panel) to FLT. Verify that igniters are not operating (Fig. 203). On airplanes with 5 position rotary start switch, with start lever in CUTOFF, rotate engine start switch (forward overhead panel) to RT IGN, LT IGN, GRD and FLT. Verify that igniters are not operating (Fig. 203).
WARNING: THE CURRENTS INVOLVED IN THE IGNITION SYSTEM CAN BE FATAL. DO NOT TOUCH IGNITER PLUGS WHILE THE IGNITION SYSTEM IS OPERATING.
WARNING: HIGH VOLTAGES WILL BE ENCOUNTERED WHILE FIRING IGNITERS. STAND CLEAR OF TAILPIPE; THERE MAY BE SUFFICIENT AMOUNT OF FUEL VAPOR PRESENT IN THE ENGINE TO CONSTITUTE AN EXPLOSIVE MIXTURE.
(4)
On airplanes with 4 position rotary start switch, with engine start switch still in FLT position, move start lever to IDLE detent. Verify that igniter sparking sound is heard. On airplanes with 5 position rotary start switch, with engine start switch in FLT position, move start lever to IDLE detent. Verify that igniter sparking sound is heard from both igniters.
(5)
On airplanes with 4 position rotary start switch, with start lever in IDLE, rotate engine start switch to LOW IGN position. Verify that igniter sparking sound is heard. On airplanes with 5 position rotary start switch, with start lever in IDLE, rotate engine start switch to LT IGN and RI IGN positions. Verify that igniter sparking sound is heard from each igniter at these switch positions.
(6)
Return engine start switch to OFF position.
(7)
Push (close) START VALVES circuit breaker.
504
71-09-100 Page 210 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. May 15/79
NOTE: Above procedure is a general check only. For a detailed ignition system test, refer to Chapter 74, Ignition System.
5. Motor Engine Procedure
A. General
(1) An engine motoring run is required after an unsatisfactory start to clear the engine of trapped fuel and vapors. A motoring run may also be accomplished to bleed and depreserve the engine fuel control and to prime the constant speed drive unit.
May 15/79 71-09-100 Page 210A/210B BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
B. Motor Engine
(1)
Perform Engine Operation Preparations in par. 3.
(2)
Check that engine start switch is positioned to OFF.
(3)
Move engine start switch to GRD position and observe N2 rpm increase.
NOTE: Starter duty cycle for motoring engine is 2 minutes on and 5 minutes off.
CAUTION: IF THIS SWITCH IS RETURNED TO OFF PRIOR TO END OF MOTORING RUN, IT MUST NOT BE ENGAGED UNTIL 30 SECONDS AFTER ENGINE AND STARTER HAVE STOPPED ROTATING.
CAUTION: DO NOT EXCEED STARTER DUTY CYCLE OR DAMAGE TO STARTER MAY RESULT.
(4)
Check N1 and N2 tachometer indicators for correct direction of rotation.
(5)
Deleted