(1) Absolute or Extensive Sealing Areas
(a)
Clean the area where seal fittings will seal (par. 3).
(b)
Pass wire bundle through the cutout provided.
500
51-31-0 Page 210 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. May 01/98
F85755
500 Application of Aerodynamic Smoother
Nov 01/75 Figure 206 51-31-0
Page 211
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
(c) Encircle each individual wire in the bundle with coiled spacers. 1) Coil spacers two to four turns on each wire. 2) Position spacers on the wires so as to be completely enveloped by the seal
assembly when it is secured in the cutout (Detail A, Fig. 207).
NOTE: Three wires or less can be separated by solid plastic wire separators. Four or more wires must be separated by wire coil separators.
(d)
Place seal fitting halves around wires in the bundle with flanges on the on-pressure side.
(e)
Position fitting so that wire separators are entirely within fitting.
(f)
Place a strong piece of string about 8 inches long against the seal assembly parallel with the wires.
(g)
Wrap fitting halves with three turns of 1-1/2 inch wide masking tape (Permacel Tape No. 70 or No. 85, American Tuck Tape No. 210, or equivalent) (Detail B, Fig. 207).
(h)
Crimp the 1-1/2 inch wide masking tape around the seal assembly ends so as to center the wire bundle.
(i)
Wrap crimped end with three turns of 3/4 inch masking tape (Detail C, Fig. 207).
(j)
Position seal plate and filler on off-pressure side and secure seal assembly in place (Detail D, Fig. 207).
(k)
Puncture paper masking tape over the most convenient injection hole in seal fitting.
(l)
Inject sealant, using a sealant gun at a pressure of approximately 100 psi until sealant without visible evidence of entrapped air emerges from both notches in the outer periphery of the seal assembly mounting flanges.
(m)
Apply fillets of sealant along joints of the filler and seal over the fasteners in the center of the filler.
(n)
Remove tape after sealant has cured (16 to 24 hours) by pulling rip string and unwinding.
(o)
Where a coverplate is used to cover an unused opening, apply a faying surface seal between plate and structure (Detail E, Fig. 207).
(2) Intermediate Sealing Area
NOTE: In fuel vapor barrier areas the same procedure of installation as outlined in par. 10.A.(1) is followed except the coil spacers are not used.
500
51-31-0 Page 212 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. Nov 1/75
F85760
500 Installation and Sealing of Electrical Seal Fittings
Nov 01/75 Figure 207 51-31-0
Page 213
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.
B. Single Cutout
(1)
Absolute or Extensive Sealing Area
NOTE: Procedure is identical as outlined for multiple cutout except no seal plate or filler is involved.
(2)
Intermediate Sealing Area
NOTE: Procedure is identical as outlined for multiple cutout, except no seal plate or filler is involved.
11. Apply Fuel Seal
A. For information on integral fuel tank sealing, refer to Chapter 28, Fuel. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737 AMM 飞机维护手册 结构 STRUCTURES(46)