 1.
 Reason for the Job

__________________
 Refer to the MPD TASK: 223000-01


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 34-10-00-860-004 IR Alignment Procedure
 3. Job Set-up
__________ Subtask 22-30-00-860-056
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).


 (2)
 Make sure that the ventilation of the electronics racks operates correctly.

 (3)
 Align the IRs. NOTE : Two ADIRS's are necessary to do this test (Ref. TASK 34-10-00-

____
 860-004).


 (4)
 On the maintenance panel 50VU, release the ENG/FADEC GND PWR 1 and 2 pushbutton switches (ON legends on).

 (5)
 Check that the throttle control levers are in the IDLE STOP position.

 (6)
 On the glareshield, on the FCU, push the FD pushbutton switches to

 


 disengage the FDs (the legends are off). R
 Subtask 22-30-00-865-061
 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU ENGINE/2/FADEC A/AND EIU 2 2KS2 A05 49VU ENGINE/1/FADEC A/AND EIU 1 2KS1 A04 49VU AUTO FLT/FCU/1 9CA1 B05 49VU AUTO FLT/FMGC/1 10CA1 B02 121VU AUTO FLT/FCU/2 9CA2 M21 121VU AUTO FLT/FMGC/2 10CA2 M17 121VU ENGINE/ENG2/FADEC B 4KS2 Q40 121VU ENGINE/ENG1/FADEC B/AND EIU 1 4KS1 R41
R
 4. Procedure
_________
 Subtask 22-30-00-710-058
 A. Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the MCDU:  The AIDS menu comes into view.
 -Push the line key adjacent to
 AIDS indication.

 2.
 Push the line key adjacent to the  The AIDS PARAM CALL-UP page comes into CALL-UP PARAM indication. view.

 3.
 Push the line key adjacent to the  The AIDS PAR LAB CALL-UP page comes PARAM LABEL CALL-UP indication. into view.

 4.
 On the MCDU keyboard set:
 7C/1/354/01.

 

 1EFF : ALL 1 22-30-00Page 502 1 1 Feb 01/01 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
5.
 Push the line key 1L.

6.
 On the MCDU keyboard set: 7C/2/354/10.

 7.
 Push the line key 4L.

8.
 Open the circuit breaker 10CA1.

 9.
 On the glareshield, on the FCU, push the A/THR pushbutton switch.

10.
 On the right throttle lever, push the A/THR instinctive disconnect pushbutton switch.

11.
 On the glareshield, on the FCU, push the A/THR pushbutton switch.

 12.
 On the right throttle lever, push the A/THR instinctive disconnect pushbutton switch. Keep it pushed for more than 15 seconds.


7C, 1, 354, 01 come into view in their associated boxes with label 354 bits status.
7C, 2, 354, 10 come into view in their associated boxes with label 354 bits status.
The A/THR pushbutton switch comes on.On the PFDs:
 -green SPEED comes into view,
 -white A/THR comes into view.
 On MCDU AIDS PARAM LABEL page check that the bit 27 of the label 354 is set to 0.
The A/THR pushbutton switch goes off.On the PFDs:
-green SPEED goes out of view,
 -white A/THR goes out of view.
 On MCDU AIDS PARAM LABEL page check that bit 27 of label 354 remains to 0.
Same result as step 9.
The A/THR pushbutton switch goes off.On the PFDs:
-green SPEED goes out of view,
-white A/THR goes out of view.
 On MCDU AIDS PARAM LABEL page check that bit 27 of label 354 is set to 1.


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
13.
 Open and close the circuit breaker 10CA2 (wait for safety tests).
 