> Inflation Levers
Squeeze and pull up –
· Releases mask from stowage box
· Releases OXY ON flag when stowage box doors open
· Activates oxygen and microphone
· Inflates mask harness when inflation lever is squeezed
· Flow indicator shows a yellow cross momentarily as harness inflates.
AIRCRAFT GENERAL
Sec. 6.1 Page 90 737
Rev. 11/15/02 #41 Continental Flight Manual
BCD OXYGEN MASK AND REGULATOR
< NORMAL / 100% Switch
N (normal) – Supplies air / oxygen mixture on demand (ratio depends on
cabin altitude).
100% – Supplies 100% oxygen on demand.
= Inflation Lever
Squeeze –
· Inflates mask harness
· Flow indicator shows a colored cross momentarily as harness inflates.
> EMERGENCY / PRESS TO TEST Selector
Rotate – Supplies 100% oxygen under positive pressure at all cabin
altitudes.
PRESS TO TEST – Tests positive pressure supply to regulator.
? Protective Strip
There is a protective strip of clear plastic on the top portion of the lens.
This strip can be peeled off using the tab on the right side in case of icing
caused by a rapid depressurization.
AIRCRAFT GENERAL
737 Sec. 6.1 Page 91
Flight Manual Continental Rev. 11/15/02 #41
BCD FLIGHT CREW OXYGEN MASK USAGE
Donning Instructions
To don the oxygen mask accomplish the following:
- Grasp the regulator by the red inflation levers with the hand nearest the
stowage box.
· Squeeze the inflation levers while pulling the mask from the box.
· Pull the mask across in front of you, toward the center of the aircraft (to
ensure ample hose extension) while rolling the mask face-up.
· Lean slightly toward the center of the aircraft and bring the mask toward
your face so that the lower portion of the mask contacts your chin first. Roll
the top of the mask toward your forehead so the harness goes over and
behind your head.
· Release the inflation levers so the harness holds the mask in place.
AIRCRAFT GENERAL
Sec. 6.1 Page 92 737
Rev. 11/15/02 #41 Continental Flight Manual
Stowing Instructions
To stow the oxygen mask accomplish the following:
· Set the N / 100% regulator control to 100%.
· Ensure that the EMERGENCY oxygen control knob is off.
· Coil the supply hose into the bottom of the stowage box, making the largest
diameter possible.
· Ensure that the harness is completely deflated.
· Hold the mask by the regulator, with the facepiece down and the inside of
the mask toward you.
· Grasp the harness and pull it downward so the cross straps are below the
facepiece. Allow the excess harness to hang downward.
Caution: Do not push the harness cross straps into or behind the nosepiece.
Doing this may cause the cross straps to hang up on the mask
during inflation.
· Position the supply hose down the center of the facepiece.
· Insert the mask-regulator assembly into the stowage box, beginning with
the harness (regulator up).
· Press down on the assembly until the mask-regulator is fully seated against
the stop in the stowage box.
· Close the left-hand door. The OXY ON flag will slide into view at the center
of the door.
· Close the right-hand door, ensuring not to pinch the hose.
· Press, then release the TEST AND RESET control lever on the left-hand door.
Ensure that the OXY ON flag disappears when the control lever is released.
WARNING: Do not squeeze the red inflation levers during stowing.
Doing this will inflate the harness and prevent the correct
stowing of the mask.
AIRCRAFT GENERAL
737 Sec. 6.1 Page 93
Flight Manual Continental Rev. 11/15/02 #41
AIRCRAFT GENERAL
Sec. 6.1 Page 94 737
Rev. 11/15/02 #41 Continental Flight Manual
INTENTIONALLY LEFT BLANK
AIRCRAFT GENERAL
737 Sec. 6.1 Page 95
Flight Manual Continental Rev. 11/15/02 #41
EMERGENCY EQUIPMENT & EXITS
FIRE EXTINGUISHERS
WARNING: Whenever a fire is encountered on the aircraft, land at the
nearest suitable airport unless it can be positively verified that
the fire has been extinguished.
Water
Water fire extinguishers contain a solution of water mixed with anti-freeze. The
container is pressurized by a C02 cartridge when the extinguisher handle is
rotated fully clockwise. The extinguisher should be used on fabric, paper, or
wood fires only.
Caution: Do not use on electrical or grease type fires.
To Use: Remove from stowage. Rotate the handle fully clockwise. Aim at
the base of the fire and press the trigger.
中国航空网 www.aero.cn