SP.TOC.0.4 D6-30151-425
Supplementary Procedures -
Table of Contents
Intentionally
Blank
April 01, 2001
747 Operations Manual
Supplementary Procedures Chapter SP
Introduction Section 0
Copyright © The Boeing Company. See title page for details.
D6-30151-425 SP.0.1
General
This chapter contains procedures (adverse weather operation, engine crossbleed
start, and so on) accomplished as required rather than routinely performed on each
flight. Systems tests are described in the System Description chapter of the
applicable system.
Note: System tests are not normally a flight crew action.
Procedures accomplished in flight, or those that are an alternate means of
accomplishing normal procedures (such as manual engine start), are usually
accomplished by recall. Infrequently used procedures, not normally accomplished
(such as engine crossbleed start) are usually accomplished by reference.
Supplementary procedures are provided by section. Section titles correspond to
the related chapter title for the system being addressed except for the Adverse
Weather section.
December 01, 1999
747 Operations Manual
Copyright © The Boeing Company. See title page for details.
SP.0.2 D6-30151-425
Supplementary Procedures -
Introduction
Intentionally
Blank
April 1, 2000
747 Operations Manual
Supplementary Procedures Chapter SP
Airplane General Section 1
Copyright © The Boeing Company. See title page for details.
D6-30151-425 SP.1.1
Oxygen Test
Oxygen Mask ................................................................................Stowed
Verify doors closed.
FLIGHT INTERPHONE TRANSMITTER Selector.......................MIC
SPEAKER Selector ............................................................................ON
STATUS DISPLAY Switch...............................................................Push
Crew Oxygen Pressure.......................................................Check EICAS
Note oxygen pressure.
RESET/TEST Slide Lever ................................................Push and Hold
Verify yellow cross appears momentarily in flow indicator.
EMERGENCY/TEST Selector .........................................Push and Hold
Simultaneously push Emergency/Test selector and Reset/Test slide lever.
Verify yellow cross appears continuously in flow indicator.
PUSH-TO-TALK Switch ................................................................... INT
Verify oxygen flow sound is heard through the flight deck loudspeaker.
EMERGENCY/TEST Selector ....................................................Release
RESET/TEST Slide Lever ...........................................................Release
Verify yellow cross no longer appears in flow indicator.
NORMAL/100% Selector .............................................................. 100%
Leave N/100% selector in 100% position.
Crew Oxygen Pressure.......................................................Check EICAS
Verify pressure decreases no more than 30 psi during test and pressure
adequate for dispatch.
April 01, 2001
747 Operations Manual
Copyright © The Boeing Company. See title page for details.
SP.1.2 D6-30151-425
Supplementary Procedures -
Airplane General
Intentionally
Blank
October 1, 2000
747 Operations Manual
Supplementary Procedures Chapter SP
Air Systems Section 2
Copyright © The Boeing Company. See title page for details.
D6-30151-425 SP.2.1
Air Conditioning Packs
APU-to-Pack Takeoff
After engine start:
LEFT and RIGHT ISOLATION valve switches - OFF
Leave APU running to supply air to pack 2.
Before takeoff:
PACKS 1 and 3 control selectors - OFF
After takeoff:
PACK control selector (One only) - NORM
After engine thrust is reduced from takeoff to climb, position one Pack
Control selector to NORM.
PACK control selector (Remaining pack) - NORM
When cabin pressurization stabilizes, position remaining Pack Control
selector to NORM.
LEFT and RIGHT ISOLATION valve switches - ON
APU selector - OFF
Ground Air Conditioning Cart Use
Before connecting ground air conditioning cart:
PACK control selectors - OFF
Allows cart to operate at maximum efficiency.
RECIRCULATION FANS switches - OFF
Allows cart to operate at maximum efficiency.
After disconnecting ground air conditioning cart:
PACK control selectors - AUTO
RECIRCULATION FANS switches - ON