• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-09-19 15:45来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

January 2005
34-61

- 142 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved

A34-61-00-076.fm
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL

FMCS - OFP CROSSLOAD PAGE THIS PAGE INTENTIONALLY LEFT BLANK
January 2005
34-61

- 143 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved

A34-61-00-076.fm
SOUTHWEST AIRLINES.

FMCS - OFP CROSSLOAD PAGE General
The OFP CROSSLOAD page lets you review and, if necessary, transfer the operational flight program (OFP) between the primary and secondary FMCs.
Page Access
This page shows for any of these conditions:
-If, during ground power-up, the primary FMC finds a mismatch
between its valid OFP and that of the secondary FMC -An OFP with a different update version is loaded into one FMC -Selection of the CROSSLOAD prompt on the FMCS BITE INDEX
page if there is an OFP mismatch currently.

If there is no mismatch between the OFPs but there is an analog discrete mismatch, the ANALOG DISCRETE page shows with the specific mismatch highlighted.
OFP Crossload Page Information
Line select key 1L and 1R show the OFP software part numbers for the left and right FMCs if there is an OFP mismatch. If there is no mismatch these data fields are blank.
Line select key 5L and 5R show the crossload status. These messages may show:
-COPY FROM <LEFT/RIGHT>

- CROSSLOAD FMC-L TO FMC-R 
- CROSSLOAD FMC-R TO FMC-L 
- CROSSLOAD IN PROGRESS 

January 2005 - 144 -

737-700 MAINTENANCE TRAINING MANUAL
-CROSSLOAD COMPLETE -CROSSLOAD FAIL (the data base in the source FMC did not crossload to the target FMC) -CROSSLOAD UNAVAILABLE (the source FMC can not interface with the other FMC) -SET FMC SOURCE SELECT TO BOTH ON R (shows when the primary FMC is also the target FMC).

To start the crossload, select COPY FROM LEFT or COPY FROM RIGHT on the MCDU and push the EXEC key. The message CROSSLOAD IN PROGRESS shows during the crossload process. At the end of the crossload, the message CROSSLOAD COMPLETE shows on the MCDU.
Line select key 6L shows one of these prompts:
-INDEX (selects the FMCS BITE INDEX page) -CANCEL (shows when the source FMC for the crossload has been selected but the EXEC key has not been pressed) -NEXT MISMATCH.

The NEXT MISMATCH prompt shows either the specified ANALOG DISCRETE page if there is a discrete mismatch currently or the DATABASE CROSSLOAD page if there is not a discrete mismatch but there is a data base mismatch.
If there are no more mismatches between the FMCs, the INDEX prompt shows.
This line is blank while the crossload is in progress.
34-61

SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved

A34-61-00-076.fm
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL

FMCS - OFP CROSSLOAD PAGE
NOTE:  The example on the graphic shows a mismatch between the OFPs and also the position of the right ECS pack switch and a navigation data base mismatch between the FMCs.
January 2005
34-61

- 145 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL

 

 


OR

 

OR


A34-61-00-076.fm
FMCS - OFP CROSSLOAD PAGE

January 2005
34-61

- 146 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved

A34-61-00-052.fm
SOUTHWEST AIRLINES.

FMCS - DATABASE CROSSLOAD PAGE
The database crossload page lets you review and, if necessary, transfer the various data bases between the FMCs.
These are the applicable data bases:
-Model/engine
-Navigation
-Performance defaults
-Software options.


This page shows for any of these conditions:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-700 AVIONCS BITE HANDBOOK 航电自测设备手册 1(37)