EFFECTIVITY BEJ ALL 24-60-00
Page 3
D633W101-BEJ Jan 05/2002
DC DISTRIBUTION -GROUND HANDLING TRU
General
The ground handling TRU is in the P320 ground service/ handling power panel. It converts ac power into 28v dc power. These are typical loads for the ground handling 28v dc power:
*
Cargo handling
*
Refuel valves
*
Refuel quantity control/indication
*
Service interphone
*
Powered door opening system (engine cowls).
EFFECTIVITY BEJ ALL 24-60-00
Page 4
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
DC DISTRIBUTION -GROUND HANDLING TRU
EFFECTIVITY BEJ ALL 24-60-00
Page 5
D633W101-BEJ Jan 05/2002
DC DISTRIBUTION -FUNCTIONAL DESCRIPTION -POWER DISTRIBUTION
General
The dc distribution divides the electrical power dc buses into sections. The primary buses are in the ELMS power management panels P110, P210, and P310. These are the primary buses of the electrical power dc system:
*
Hot battery
*
Left dc
*
Right dc
*
Captain’s flight instrument
*
First officer’s flight instrument.
The ground handling bus is in the P320 ground service/handling power panel. The APU battery bus is in the P49 APU panel.
Hot Battery Bus
The hot battery bus divides into these:
*
Tow dc bus
*
P11 supply
*
Hot battery distribution bus.
Left and Right DC Buses
The left and right dc buses do not divide. They do supply power to P11.
Captain’s Flight Instrument Bus
The captain’s flight instrument bus divides into these buses:
*
Battery bus
*
P11 supply
*
Captain’s flight instrument distribution bus
*
Battery #2 bus.
The battery bus further divides into these:
*
P11 supply
*
Battery distribution bus.
First Officer’s Flight Instrument Bus
The first officer’s flight instrument bus does not divide. It does supply power to the P11.
EFFECTIVITY BEJ ALL 24-60-00
Page 6
D633W101-BEJ Sep 05/2002
DC DISTRIBUTION -FUNCTIONAL DESCRIPTION -POWER DISTRIBUTION
EFFECTIVITY BEJ ALL 24-60-00
Page 7
D633W101-BEJ Jan 05/2002
中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:777 AMM 飞机维护手册 电源 Electrical Power(44)