(2)
Boots
(commercially available)
(3)
Gloves - Rubber, Elbow Length
(commercially available)
(4)
Goggles - Safety
(commercially available)
(5)
Head Gear
(commercially available)
(6)
Shield - Face
(commercially available)
B. Consumable Materials
(1)
Chemical, Sodium bicarbonate - O-S-576
(2)
Cleaner, Bicarbonate of soda
(3)
Compound, Organic Corrosion Inhibiting - BMS3-23
C. Procedure
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
05-51-57
ALL ú ú 01 Page 201 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 342-005
WARNING:_______ ACIDS ACCIDENTALLY SPILLED ON SKIN, CLOTHING OR OTHER MATERIAL
SHOULD BE FLOODED IMMEDIATELY WITH CLEAN WATER. IF EYES ARE
INVOLVED FLOOD WITH COPIOUS QUANTITY OF CLEAN WATER AND CONSULT
A PHYSICIAN IMMEDIATELY.
(1) Take these precautions when you work with an acid spill condition:
(a)
Adequate protective clothing should be worn when handling or working in acid contaminated areas. 1) gloves 2) goggles 3) shield 4) aprons 5) boots 6) head gear
(b)
Wash hands after using acid neutralizing treatment solution and/or materials before eating or smoking.
(c)
Waste materials, solvents, chemical solutions, wiping rags, masking materials, etc., shall be collected and disposed of safely.
S 942-002
(2) Do these steps to isolate the contaminated areaa:
(a)
Do not allow acid spills to spread from areas of contamination.
(b)
Using plastic sheets is advised for protection of equipment beneath battery areas. If equipment is operating, venting requirements should be maintained.
(c)
Consider protecting uncontaminated areas by taping down protective material such as plastic sheets.
S 112-003
(3) Do these steps to clean the area of an acid spillage:
(a)
If equipment is adjacent to the treatment area use plastic sheets to cover the equipment to prevent inadvertent splashing of acids or treatment fluids.
(b)
Wipe up excess fluids with cloth and discard cloth into plastic container for disposition.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
05-51-57
ALL ú ú 01 Page 202 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(c) Neutralize the treatment area with a 20% cleaner, bicarbonate of soda solution applied with a brush or cloth swab. Particular attention should be given to faying surface joints. Pressure application may be required to flush the joint thoroughly.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 限制/维护检查(83)