(2) Do the operational test of the FADEC 1A on the ground (with engine non motoring) (Ref. AMM TASK 73-29-00-710-040).
F 『 EEFF : ALL E ∞∞71-50-00∞∞∞∞∞∞∞∞∞∞Page 207
E E Aug 01/99 E E ECES
E
F 『
E C F M E
E E
E 56 E
E E
4. Fault Isolation
_______________
A. If the circuit breaker (3JH1) is closed and if the test gives the maintenance message J2, 115 VAC, ECU:
R CAUTION : WHEN THE "ENG/MASTER" LEVER IS IN THE "ON" POSITION, BE VERY_______
R CAREFUL NOT TO SET THE "ENG/MODE" SELECTOR SWITCH TO "CRANK" OR
R "IGN/START".
R IF YOU DO SET THE SELECTOR SWITCH TO ONE OF THESE POSITIONS,
R THE ENGINE WILL START. THERE IS THUS A RISK OF INJURY TO
R PERSONS AND OF DAMAGE TO EQUIPMENT.
R - On the panel 115 VU, set the MASTER switch to "ON".
- do a check for 115VAC at the ECU (4000KS) pins J2/7 (Ref. ASM 74-
31/01). R - On the panel 115 VU, set the MASTER switch to "OFF".
(1) If there is 115VAC:
- replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
(2) If there is no 115VAC:
- do a check for 115VAC at the EIU-1 (1KS1) pin AC/1.
(a) If there is 115VAC:
- replace the EIU-1 (1KS1) (Ref. AMM TASK 73-25-34-000-040) and (Ref. AMM TASK 73-25-34-400-040).
1 If the fault continues:
_
- replace the J2 harness between the EIU-1 (1KS1) and the ECU (4000KS).
(b) If there is no 115VAC:
- do a check of the wiring between the EIU-1 (1KS1) pin AC/1 and the circuit breaker (3JH1).
1 If there is no continuity:
_ - repair the above wiring.
2 If there is continuity:
_
- replace the C/B-ENGINE/IGN/ENG1/SYS B (3JH1).
(3) If the fault continues:
- make sure that there is no ground signal at the EIU-1 (1KS1) pin AA/5B.
B. If the circuit breaker (3JH1) is open:
- close it.
(1) If the circuit breaker trips:
- remove the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001)
- remove the EIU-1 (1KS1) (Ref. AMM TASK 73-25-34-000-040).
F 『 EEFF : ALL E ∞∞71-50-00∞∞∞∞∞∞∞∞∞∞Page 208
E E Nov 01/02 E E ECES
E E 56 E E E (2) If the circuit breaker trips again:
F 『
E C F M E
E E
- do a check and repair the wiring for short to ground between the EIU-1 pin AC/1 and the circuit breaker (3JH1).
(a) If the fault continues:
- replace the C/B-ENGINE/IGN/ENG1/SYS B (3JH1).
(3) If the circuit breaker stays closed:
- install the EIU-1 (1KS1) (Ref. AMM TASK 73-25-34-400-040).
(a) If the circuit breaker trips:
- replace the EIU-1 (1KS1) (Ref. AMM TASK 73-25-34-000-040) and (Ref. AMM TASK 73-25-34-400-040).
(b) If the circuit breaker stays closed:
- install the ECU (4000KS) (Ref. AMM TASK 73-21-60-400-001).
1 If the circuit breaker trips:
_
- replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
2 If the circuit breaker trips again:
_
- do a check and repair the wiring between the ECU (4000KS) pins J2/7 and the EIU-1 pin AC/4.
(4) If the fault continues:
- make sure that there is no ground signal at the EIU-1 (1KS1) pin AA/5B.
C. Do the test given in Para. 3.A.
F 『 EEFF : ALL E ∞∞71-50-00∞∞∞∞∞∞∞∞∞∞Page 209
E E Nov 01/02 ERE
ECES E
F 『
E C F M E
E E
E 56 E
E E
TASK 71-50-00-810-804
Loss of the 115VAC Power Supply on the ECU 2
1. Possible Causes
_______________
- EIU-2 (1KS2)
- ECU (4000KS)
- J2 harness
- wiring
- C/B-ENGINE/IGN/ENG2/SYS B (3JH2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R AMM 73-21-60-000-001 Removal of the Electronic Control Unit (ECU)(4000KS) AMM 73-21-60-400-001 Installation of the Electronic Control Unit R (ECU)(4000KS) AMM 73-25-34-000-040 Removal of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-25-34-400-040 Installation of the Engine Interface Unit (EIU) (1KS1,1KS2) AMM 73-29-00-710-040 Operational Test of the FADEC on the Ground (with Engine non Motoring) ASM 74-31/01
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 动力装置 POWER PLANT(10)