GENERATOR LOAD ON THE GROUND
TEMP ISA ISA +20 ISA +35
MAX ALT (FT)
0 ENPGA SCTKASRT 100 % (90 KVA)0 %% ((7900 KKVVAA)) %% ((5705 KKVVAA))
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
ENVELOPE
A318/A319/A320/A321 FLEET LIM-49-20 P 4/8
FCOM 19 AUG 10
Continued from previous page
GENERATOR LOAD ON THE GROUND
TEMP ISA ISA +20 ISA +35
MAX ALT (FT)
8 000 ENPGA SCTKASRT 100 % (90 KVA)0 %% ((7900 KKVVAA)) %% ((4505 KKVVAA))
9 200 ENPGA SCTKASRT0 %% ((8940 KKVVAA)) %% ((5646 KKVVAA)) %% ((3368 KKVVAA))
GENERATOR LOAD
Applicable to:
GENERATOR LOAD IN FLIGHT
TEMP ISA ISA +20 ISA +35
MAX ALT (FT)
25 000 100 % (90 KVA) 100 % (90 KVA) 100 % (90 KVA)
30 000 100 % (90 KVA) 92 % (83 KVA) 84 % (76 KVA)
35 000 86 % (78 KVA) 71 % (64 KVA) 67 % (60 KVA)
39 000 70 % (63 KVA) 56 % (51 KVA) 53 % (48 KVA)
GENERATOR LOAD ON THE GROUND
TEMP ISA ISA +20 ISA +40
MAX ALT (FT)
0 ENPGA SCTKASRT % % ( 3(654 K KVVAA) )(1)
9 200 ENPGA SCTKASRT 57 % (51 KVA)
100 % (90 KVA) 100 % (90 KVA)
60 % (54 KVA)
(1) generator load with maximum air conditioning demand.
GENERATOR LOAD
Applicable to:
,
,
MSN,,,
GENERATOR LOAD IN FLIGHT
Altitude (ft) ISA ISA +10 ISA +20 ISA +30 ISA +35
25 000 100 % (90 KVA) 100 % (90 KVA) 100 % (90 KVA) 100 % (90 KVA) 100 % (90 KVA)
30 000 100 % (90 KVA) 100 % (90 KVA) 100 % (90 KVA) 100 % (90 KVA) 98 % (88 KVA)
35 000 93 % (84 KVA) 91 % (82 KVA) 88 % (79 KVA) 84 % (76 KVA) 79 % (71 KVA)
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
ENVELOPE
A318/A319/A320/A321 FLEET LIM-49-20 P 5/8
FCOM 19 AUG 10
Continued from previous page
GENERATOR LOAD IN FLIGHT
Altitude (ft) ISA ISA +10 ISA +20 ISA +30 ISA +35
39 000 71 % (64 KVA) 69 % (62 KVA) 68 % (61 KVA) 63 % (57 KVA) 61 % (55 KVA)
41 000See 57 % (51 KVA) 55 % (50 KVA) 55 % (50 KVA) 54 % (49 KVA) 53 % (48 KVA)
GENERATOR LOAD ON THE GROUND
Altitude (ft) MODE ISA ISA +10 ISA +20 ISA +30 ISA +35 ISA +40
ENG START 100 %
(90 KVA)
100 %
(90 KVA)
98 %
(88 KVA)
85 %
(77 KVA)
79 %
(71 KVA)
68 %
(61 KVA) (1) 14 500
PACKS 100 %
(90 KVA)
100 %
(90 KVA)
91 %
(82 KVA)
78 %
(70 KVA)
70 %
(63 KVA)
58 %
(52 KVA)
ENG START 100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
91 %
(82 KVA)
83 %
(75 KVA)
72 %
9 200 (65 KVA)
PACKS 100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
87 %
(78 KVA)
78 %
(70 KVA)
67 %
(60 KVA)
ENG START 100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
92 %
(83 KVA)
84 %
(76 KVA)
74 %
8 000 (67 KVA)
PACKS 100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
89 %
(80 KVA)
79 %
(71 KVA)
70 %
(63 KVA)
ENG START 100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
90 %
(81 KVA)
81 %
0 (73 KVA)
PACKS 100 %
(90 KVA)
100 %
(90 KVA)
100 %
(90 KVA)
91 %
(82 KVA)
83 %
(75 KVA)
75 %
(68 KVA)
(1) Generator load with maximum bleed performance.
(2) Only on aircraft certified up to that flight level.
ELECTRICAL POWER/AIR BLEED EXTRACTION
Applicable to:
‐ Electric power extraction :
At or below 25 000 ft :
ISA +20 °C and below....................................................................................................... 90 KVA
‐ Air bleed extraction (in flight) for air conditioning :
One air conditioning pack up to 20 000 ft with generator load at or below 69 % (62 KVA)
Two air conditioning packs up to 15 000 ft with generator load at or below 88 % (79 KVA)
‐ Air bleed extraction (in flight) for engine start up to 20 000 ft :
with 82 % (74 KVA) generator load at or below ISA
with 75 % (68 KVA) generator load at ISA +20
with 69 % (62 KVA) generator load at ISA +35
‐ Air bleed extraction for wing anti-icing is not permitted.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
ENVELOPE
A318/A319/A320/A321 FLEET LIM-49-20 P 6/8
FCOM 19 AUG 10
ELECTRICAL POWER/AIR BLEED EXTRACTION
Applicable to:
‐ Electric power extraction :
At or below 25 000 ft :
ISA +35 °C and below....................................................................................................... 90 KVA
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
A320机组操作手册FLIGHT CREW OPERATING MANUAL 5(84)