LIM-49-PLP PRELIMINARY PAGES
TABLE OF CONTENTS......................................................................................................................................1/2
LIM-49-10 GENERAL
GENERAL............................................................................................................................................................1/2
LIM-49-20 ENVELOPE
ENVELOPE......................................................................................................................................................... 1/8
GENERATOR LOAD...........................................................................................................................................3/8
ELECTRICAL POWER/AIR BLEED EXTRACTION............................................................................................. 5/8
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
PRELIMINARY PAGES - TABLE OF CONTENTS
Intentionally left blank
A318/A319/A320/A321 FLEET LIM-49-PLP-TOC P 2/2
FCOM 19 AUG 10
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
GENERAL
A318/A319/A320/A321 FLEET LIM-49-10 P 1/2
FCOM 19 AUG 10
GENERAL
Applicable to: ALL
OIL QUANTITY
The APU may be started and operated even if the LOW OIL LEVEL ECAM advisory is displayed.
Maintenance action is required within next 10 h of APU operation.
Applicable to: ALL
APU STARTER
After 3 starter motor duty cycles, wait 60 min before attempting 3 more cycles.
Applicable to:
ROTOR SPEED
Maximum N (ECAM display)....................................................................................................107 %
Applicable to:
ROTOR SPEED
Maximum N (ECAM display)....................................................................................................107 %
Note: The APU automatically shuts down at 107 % N speed, that appears on the ECAM.
This corresponds to an actual N speed of 105 %.
Applicable to:
,
,
MSN,,,
ROTOR SPEED
Maximum N (ECAM display)....................................................................................................107 %
Note: The APU automatically shuts down at 107 % N speed, that appears on the ECAM.
This corresponds to an actual N speed of 106 %.
Applicable to:
EGT
Maximum EGT.........................................................................................................................725 °C
Maximum for start................................................................................................................ 1 038 °C
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
GENERAL
A318/A319/A320/A321 FLEET LIM-49-10 P 2/2
FCOM 19 AUG 10
Applicable to:
EGT
Maximum EGT for start :
Below 25 000 ft....................................................................................................................... 900 °C
Above 25 000 ft.......................................................................................................................982 °C
Maximum EGT, with APU running :
682 °C, with 5 s confirmation ‐ time for shutdown, or
‐ From 700 °C to 742 °C for immediate shutdown, depending on the ambient temperature.
Applicable to:
,
,
MSN,,,
EGT
Maximum EGT.........................................................................................................................675 °C
Maximum for start (below 35 000 ft)....................................................................................1 090 °C
Maximum for start (above 35 000 ft)....................................................................................1 120 °C
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
ENVELOPE
A318/A319/A320/A321 FLEET LIM-49-20 P 1/8
FCOM 19 AUG 10
ENVELOPE
Applicable to:
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
ENVELOPE
A318/A319/A320/A321 FLEET LIM-49-20 P 2/8
FCOM 19 AUG 10
ENVELOPE
Applicable to:
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
LIMITATIONS
APU
ENVELOPE
A318/A319/A320/A321 FLEET LIM-49-20 P 3/8
FCOM 19 AUG 10
ENVELOPE
Applicable to:
,
,
MSN,,,
GENERATOR LOAD
Applicable to:
GENERATOR LOAD IN FLIGHT
TEMP ISA ISA +20 ISA +35
MAX ALT (FT)
25 000 100 % (90 KVA) 100 % (90 KVA) 99 % (89 KVA)
30 000 95 % (86 KVA) 89 % (80 KVA) 84 % (76 KVA)
35 000 74 % (67 KVA) 71 % (64 KVA) 67 % (60 KVA)
39 000 59 % (53 KVA) 57 % (51 KVA) 53 % (48 KVA)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
A320机组操作手册FLIGHT CREW OPERATING MANUAL 5(83)