46 U.S. gallons in 5-gallon increments. The RIGHT pointer sweeps an
identical scale for the right tank. Each scale is marked with a yellow
arc from 0 to 14 U.S. gallons. The indicators are calibrated to read '0'
when no usable fuel remains. Each indicator also provides an output
signal to illuminate the FUEL caution light when the fuel quantity goes
below approximately 14 gallons in each tank. The fuel quantity
indications are derived from float-type fuel-level sensors installed in
each main tank. The indicator is internally lighted. 28 VDC for fuel
quantity system operation is supplied through the 5-amp FUEL QTY /
HOBBS circuit breaker on Main Bus 1.
• Note •
When the fuel tanks are 1/4 full or less, prolonged
uncoordinated flight such as slips or skids can uncover the
fuel tank outlets. Therefore, if operating with one fuel tank dry
or if operating on LEFT or RIGHT tank when 1/4 full or less, do
not allow the airplane to remain in uncoordinated flight for
periods in excess of 30 seconds.
Revision 02: 08-26-09
52 of 58 13772-130
Section 9 Cirrus Design
Supplements SR22
Fuel Caution Light
The amber FUEL caution light in the annunciator panel comes on to
indicate a low fuel condition. The light is illuminated by switches in the
fuel quantity indicator if the fuel quantity in both tanks drops below
approximately 14 gallons (28 gallons total with tanks balanced in level
flight). Since both tanks must be below 14 gallons to illuminate the
light, the light could illuminate with as little as 14 gallons in one tank
during level flight if the other tank is allowed to run dry. If the FUEL
caution light comes on in flight, refer to the Fuel Quantity gages to
determine fuel quantity. The light is powered by 28 VDC through the 2-
amp ANNUN / ENGINE INST circuit breaker on the Essential Bus.
Revision 02: 08-26-09
13772-130 53 of 58
Cirrus Design Section 9
SR22 Supplements
Exterior Lighting
The airplane is equipped with wing tip navigation lights with integral
anti-collision strobe lights and recognition Lights. The landing light is
located in the lower cowl.
Recognition Lights
The airplane is equipped with recognition lights on the leading edge of
the wing tips. The lights are controlled through the landing light switch
on the instrument panel bolster. 28 VDC for recognition light operation
is supplied through the 5-amp REC/INST LTS circuit breaker on Main
Bus 1.
Revision 02: 08-26-09
54 of 58 13772-130
Section 9 Cirrus Design
Supplements SR22
Environmental System
Cabin heating and ventilation is accomplished by supplying
conditioned air for heating and windshield defrost and fresh air for
ventilation. The environmental system consists of a fresh air inlet in
the lower RH cowl, a heat exchanger around the RH engine exhaust
muffler, an air mixing chamber, air ducting for distribution, a distribution
manifold, a windshield diffuser, and crew and passenger air vents. An
optional 3-speed blower fan is available to supplement airflow when
ram air may be inadequate such as during ground operation.
Fresh air enters the cabin air distribution system through a NACA vent
on the RH lower cowl and is ducted to the air mixing chamber mounted
to the forward side of the firewall. Fresh air also enters the upper RH
cowl inlet, flows through the upper cowl, and is ducted to a heat
exchanger surrounding the RH engine exhaust muffler. The heated air
is then routed to the air mixing chamber to be mixed with the fresh air.
The mixed air is then distributed by either ram air or by optional blower
fan to the distribution manifold mounted to the center, aft side of the
firewall. The distribution manifold uses butterfly valves to control
airflow to the floor and defrost vents. Airflow is ducted directly to all
panel air vents.
The crew panel air vents are chest high outlets mounted in the RH and
LH bolster panels. The crew floor air vents are mounted to the bottom
of each kick plate. The passenger panel air vents are chest high
outlets mounted in the armrests integral to the LH and RH cabin wall
trim panels. The passenger floor air vents are mounted to the bottom
portion of the LH and RH cabin wall trim panels. The windshield
diffuser, located in the glareshield assembly, directs conditioned air to
the base of the windshield. Temperature, volume, and flow selection
are regulated by manipulation of the cabin airflow, cabin vents, and
cabin temperature selector knobs on the lower RH side of the
instrument panel. The optional blower fan is powered by 28 VDC
supplied through 15-amp Fan breaker on Main A/C Bus 2.
 