曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
to a gas and in doing so, absorbs heat. The evaporator then absorbs
the heat from the air passing over the coils and the moisture from the
air condenses and is drained overboard through the belly of the
aircraft. From the evaporator, the refrigerant vapor returns to the
compressor where the cycle is repeated.
During normal air-conditioning operation, ram air from the fresh air
intake flows into the evaporator assembly, is cooled as it passes
through the evaporator coils, and is then ducted forward to the
distribution manifold. During maximum air-conditioning operation - or
recirculation mode - the fresh air valve closes and valves in the
evaporator assembly open allowing cabin air to be recirculated and
further cooled as the air passes through the evaporator coils and
ducted forward to the distribution manifold.
Conditioned air is circulated through the system by ram air or by the
blower fan mounted adjacent to the evaporator.
Airflow Selection
Serials before G3 Wing; The airflow selector on the system control
panel regulates the volume of airflow allowed into the cabin distribution
system through a mechanical linkage to a butterfly valve in the
distribution manifold mounted to the aft firewall. When the selector dial
exceeds the full open position, the 3-speed blower fan is turned on.
Serials with G3 Wing; The airflow selector on the system control panel
regulates the volume of airflow allowed into the cabin distribution
system through the use of an electro-mechanical linkage to a butterfly
valve in the mixing chamber on the forward firewall. When the airflow
selector fan speed is moved to the 1, 2, or 3 position the electromechanical
linkage actuates the butterfly valve to the full open
position. The air is then distributed by the variable speed blower fan to
the distribution manifold mounted to the center, aft side of the firewall
Revision 01: 03-27-07
P/N 13772-127 11 of 14
Cirrus Design Section 9
SR22 Supplements
Vent Selection
Conditioned air from the distribution manifold can be proportioned and
directed to passengers and/or the windshield by manipulating the
cabin vent selector. The selector is mechanically linked to butterfly
valves at the entrances to the windshield diffuser and the cabin floor
ducting. There is continuous airflow to the panel and armrest eyeball
outlets. Each occupant can control the flow rate from 'off' to maximum
by rotating the nozzle.
When the selector is in the far left position, both butterfly valves are
closed providing maximum airflow to the panel and armrest eyeball
outlets.
Rotating the selector a quarter-turn clockwise opens the cabin floor
butterfly valve allowing airflow to the rear seat foot warmer diffusers
and the front seat outlets mounted to the underside of each kickplate.
Rotating the selector another quarter-turn clockwise opens the
windshield diffuser butterfly valve which permits shared airflow to the
defrosting mechanism and cabin floor outlets.
When the selector is in the far right position, the cabin floor butterfly
valve is closed providing maximum airflow to the windshield diffuser.
When the full/max defrost position is selected, the air-conditioner is
activated to provide conditioned, dry air to the diffuser to facilitate
windshield defogging.
Temperature Selection
The temperature selector is mechanically linked to the hot and cold air
valves. Rotating the selector simultaneously opens and closes the two
valves, permitting hot and cold air to enter the air-mixing chamber.
When the temperature selector is moved to the snowflake symbol, the
butterfly valve on the firewall completely closes and the air-conditioner
is activated. When recirculation symbol is selected, the fresh air valve
completely closes and cabin air is recirculated to provide for maximum
air-conditioning operation. The A/C ON light will illuminate when the
snowflake or recirculation symbol is selected.
Revision 01: 03-27-07
12 of 14 P/N 13772-127
Section 9 Cirrus Design
Supplements SR22
Figure - 2 (Sheet 1 of 2)
COLD
HOT
1
2
3
NOTE: Illustration depicts settings for Emergency Procedures
Smoke and Fume Elimination.
If source of smoke and fume is firewall forward, turn
Airflow Selector OFF.
Rotating the selector controls the volume
of airflow allowed into the cabin distribution
system by opening and closing a butterfly
valve in the distribution manifold.
When the selector dial exceeds the full
open position, the 3-speed blower fan is
turned on.
Shared airflow to the
defroster, cabin floor,
and panel outlets.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
CIRRUS DESIGN SR22西锐22飞行员操作手册和飞机飞行手册(134)