AC Synoptic Page Color Coding − Integrated Drive Generators (Page 2 of 2)
Figure 07−10−29
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−37
REV 66, Feb 01/07
AC Synoptic Page Color Coding − APU Generator (Page 1 of 2)
Figure 07−10−30
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−38
REV 66, Feb 01/07
AC Synoptic Page Color Coding − APU Generator (Page 2 of 2)
Figure 07−10−30
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
AC Synoptic Page Color Coding − AC Electrical Power Distribution
Figure 07−10−31
ELECTRICAL
Description
Vol. 2 07−10−39
REV 66, Feb 01/07
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
AC Synoptic Page Color Coding − External AC Electrical Power
Figure 07−10−32
ELECTRICAL
Description
Vol. 2 07−10−40
REV 66, Feb 01/07
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
AC Synoptic Page Color Coding − Air−Driven Generator
Figure 07−10−33
DC Synoptic Page
ELECTRICAL
Description
Vol. 2 07−10−41
REV 66, Feb 01/07
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−42
REV 66, Feb 01/07
DC Synoptic Page − TRU Power Distribution System (Page 1 of 2)
Figure 07−10−34
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−43
REV 66, Feb 01/07
DC Synoptic Page − TRU Power Distribution System (Page 2 of 2)
Figure 07−10−34
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−44
REV 66, Feb 01/07
DC Synoptic Page − Battery Power Distribution System (Page 1 of 2)
Figure 07−10−35
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−45
REV 66, Feb 01/07
DC Synoptic Page − Battery Power Distribution System (Page 2 of 2)
Figure 07−10−35
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−46
REV 66, Feb 01/07
DC Synoptic Page − DC Electrical Power Distribution (Page 1 of 2)
Figure 07−10−36
CL−604 Operating Manual
PSP 604−6
CONTROLS AND INDICATORS (CONT'D)
ELECTRICAL
Description
Vol. 2 07−10−47
REV 66, Feb 01/07
DC Synoptic Page − DC Electrical Power Distribution (Page 2 of 2)
Figure 07−10−36
CL−604 Operating Manual
PSP 604−6
EICAS MESSAGES
MESSAGE MEANING
AURAL WARNING
(IF ANY)
EMER POWER ONLY ADG is supplying the AC essential bus, and no power
is available from AC BUS 1 or 2.
WARNING
Triple Chime
AC 1 AUTOXFER Respective automatic AC bus tie function has been inhibited because of an
AC 2 AUTOXFER overcurrent condition on the respective AC bus.
AC BUS 1
Respective AC bus is unpowered.
AC BUS 2
AC ESS BUS AC essential bus is unpowered.
APU BATTERY OFF APU battery is not available.
APU GEN OFF APU generator is off-line with the APU running.
APU GEN OVLD Load current on any phase of APU GEN exceeds 100 Amp.
BATTERY BUS Battery bus is unpowered.
DC BUS 1
Respective DC bus is unpowered.
DC BUS 2
DC EMER BUS DC emergency bus is unpowered.
DC ESS BUS DC essential bus is unpowered.
GEN 1 OFF
Respective generator is OFF.
GEN 2 OFF
GEN 1 OVLD Load current on any phase of GEN 1 exceeds 100 Amp.
GEN 2 OVLD Load current on any phase of GEN 2 exceeds 100 Amp.
MAIN BATTERY OFF Main battery is not available.
AC ESS ALTN AC essential bus is powered by AC BUS 2.
AC UTIL 1 OFF
Respective AC utility bus is unpowered.
AC UTIL 2 OFF
APU BATT CHGR FAIL APU battery is not charging or APU charger has failed.
ESS TRU 1 FAIL
Respective essential transformer-rectifier unit output is less than 18 VDC.