• 热门标签

当前位置: 主页 > 航空资料 > 飞行资料 >

时间:2010-10-20 09:12来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

WINDSHIELD
DIFFUSER
AIR MIXING
PLENUM
AIR GASPER
Figure 7-15
Cabin Heating and Cooling - Serials 1637 and subsequent
March 2010
7-82 Information Manual
Section 7 Cirrus Design
Airplane Description SR20
Description and Operation-Serials 1637 & subsequent
Cabin heating and cooling is provided by mixing ventilation air from the
wing inlet with heated air provided by the muff-type heat exchanger
surrounding the right engine exhaust muffler.The conditioned air is
then forced by ram air pressure or, if option installed, by blower fan into
a distribution manifold which regulates system airflow and vent
selection. Airflow, temperature, and vent selection is accomplished
using the system control panel mounted on the right hand portion of
the instrument panel.
The optional blower fan is powered by 28 VDC supplied through 15-
amp Fan breaker on Main A/C Bus 2.
Airflow Selection
The airflow selector regulates the volume of airflow allowed into the
cabin distribution system through mechanical linkage to a butterfly
valve in the distribution manifold. If option installed, the blower fan is
turned on when the selector dial exceeds the full open position.
Vent Selection
“Conditioned” air from the distribution manifold can be proportioned
and directed to passengers and/or the windshield by manipulating the
cabin vent selector. The selector is mechanically linked to butterfly
valves at the entrances to the windshield diffuser and the cabin floor
ducting. There is continuous airflow to the panel and armrest eyeball
outlets. Each occupant can control the flow rate from 'off' to maximum
by rotating the nozzle.
When the selector is in the far left position, both butterfly valves are
closed providing maximum airflow to the panel and armrest eyeball
outlets.
Rotating the selector a quarter-turn clockwise opens the cabin floor
butterfly valve allowing airflow to the rear seat foot warmer diffusers
and the front seat outlets mounted to the underside of each kickplate.
Rotating the selector another quarter-turn clockwise opens the
windshield diffuser butterfly valve which permits shared airflow to the
defrosting mechanism and cabin floor outlets.
When the selector is in the far right position, the cabin floor butterfly
valve is closed providing maximum airflow to the windshield diffuser.
March 2010
Information Manual 7-83
Cirrus Design Section 7
SR20 Airplane Description
Temperature Selection
The temperature selector is mechanically linked to the hot air valve
and fresh air intake valve. Rotating the selector simultaneously opens
and closes the two valves, permitting hot and cold air to mix and enter
the distribution system. Rotating the selector clockwise, permits
warmer air to enter the system - counterclockwise, cooler air.
March 2010
7-84 Information Manual
Section 7 Cirrus Design
Airplane Description SR20
Pitot-Static System
The Pitot-Static system consists of a single heated Pitot tube mounted
on the left wing and dual static ports mounted in the fuselage. The
Pitot heat is pilot controlled through a panel-mounted switch. An
internally mounted alternate static pressure source provides backup
static pressure should that the primary static source becomes blocked.
Water traps with drains, under the floor in the cabin, are installed at
each Pitot and static line low point to collect any moisture that enters
the system. The traps should be drained at the annual inspection and
when water in the system is known or suspected.
Pitot Heat Switch
The heated Pitot system consists of a heating element in the pitot
tube, a rocker switch labeled PITOT HEAT, and associated wiring. The
switch and circuit breaker are located on the left side of the switch and
control panel. When the pitot heat switch is turned on, the element in
the Pitot tube is heated electrically to maintain proper operation in
possible icing conditions. Pitot heat should be used only when
required. The Pitot heat system operates on 28 VDC supplied through
the 7.5-amp PITOT HEAT/COOLING FAN circuit breaker on the Non-
Essential Bus.
Pitot Heat Light
Illumination of the amber PITOT HEAT caution light indicates that the
Pitot Heat switch is in the 'on' position and the Pitot heater is not
receiving electrical current. A current sensor on the Pitot heater power
supply wire provides current sensing. The PITOT HEAT warning light
operates on 28 VDC supplied through the 2-amp ANNUN / ENGINE
INST circuit breaker on the Essential Bus.
March 2010
Information Manual 7-85
Cirrus Design Section 7
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:西锐20飞机信息手册CIRRUS DESIGN SR20 AIRPLANE INFORMATION MA(78)