DESCRIPTION
General 08−10−1
Oxygen System 08−10−1
Description 08−10−1
Components and Operation 08−10−1
Controls and Indicators 08−10−2
Crew Oxygen Consumption Data (As per FAR 121.333) (Single Bottle) 08−10−8
Crew Oxygen Consumption Data (As per FAR 121.333) (Dual Bottle) 08−10−9
Emergency Exits 08−10−10
Main Entrance Door 08−10−10
Overwing Emergency Exit 08−10−10
Emergency Egress Lighting 08−10−10
Locating Devices 08−10−10
Components and Operation 08−10−10
Controls and Indicators 08−10−10
Miscellaneous Emergency Equipment 08−10−11
Fire Extinguishers 08−10−11
Crash Axe 08−10−11
First Aid Kit 08−10−12
Life Vest 08−10−12
Life Raft 08−10−13
Smoke Goggle Units 08−10−13
EICAS Messages 08−10−14
SUMMARY
Power Supply and Circuit Breaker Summary 08−20−1
LIST OF ILLUSTRATIONS
DESCRIPTION
Figure 08−10−1 Oxygen System Panel 08−10−3
Figure 08−10−2 Flight Deck Oxygen Masks 08−10−5
Figure 08−10−3 Quick-Donning Oxygen Mask Settings 08−10−6
Figure 08−10−4 Passenger Oxygen Control Panel 08−10−7
Figure 08−10−5 ELT System − Control Panel 08−10−11
EMERGENCY EQUIPMENT
Table of Contents
Vol. 2 08−00−1
Oct 05/06
CHAPTER 8 - EMERGENCY EQUIPMENT
08−00−1
CL−605 Flight Crew Operating Manual
PSP 605−6
TABLE OF CONTENTS
Page
TABLE OF CONTENTS
LIST OF ILLUSTRATIONS
DESCRIPTION
Figure 08−10−6 Crash Axe 08−10−12
Figure 08−10−7 Life Vest 08−10−13
Figure 08−10−8 Smoke Goggle Units 08−10−14
EMERGENCY EQUIPMENT
Table of Contents
Vol. 2 08−00−2
Oct 05/06
CL−605 Flight Crew Operating Manual
PSP 605−6
Page
GENERAL
The Challenger 605 is equipped with emergency equipment essential to the safety of the passengers
and crew.
The systems covered in this chapter are:
• Oxygen system;
• Emergency exits;
• Locating devices; and
• Miscellaneous emergency equipment.
This chapter deals only with factory-installed equipment. Individual aircraft may have other important
emergency equipment installed. Refer to your Flight Crew Operating Manual and Airplane Flight
Manual supplements for the use of items installed at the Completion Center.
OXYGEN SYSTEM
Description
An 1,850-psi gaseous oxygen system is installed at the factory to supply oxygen to the flight crew
and passengers during an emergency. The oxygen system consists of the following subsystems:
• Flight compartment;
• Passenger compartment;
• Therapeutic; and
• Portable oxygen bottle.
There are two different configurations of oxygen supply bottles installed on the Challenger 605.
Although each configuration is unique, there is no difference in operation.
Components and Operation
The oxygen baseline installation is one oxygen bottle of 115 cu. ft., installed in the wardrobe area.
There is the option of a second bottle of 40 cu. ft., which can be installed under the cockpit floor on
the right hand side.
Oxygen for the flight crew is provided through a diluter demand regulating system. A
quick-donning, inflatable harness mask is installed in a container at each side console.
Portable Oxygen Bottle
A portable oxygen bottle is provided for the crew to use in moving around the cabin, and is
normally located in a placarded position behind the pilot.
Passenger Compartment
Dropdown masks installed above all of the passenger seats and in the lavatory provide
passenger oxygen. The passenger masks are fixed-dilution (free-flow) type, which provide a
mixture of oxygen and cabin air at ambient pressure. They are designed for use at cabin
pressure altitudes below 25,000 feet. When the passenger oxygen system is active, the PAX
OXY ON caution EICAS message is displayed.
EMERGENCY EQUIPMENT
Description
Vol. 2 08−10−1
Oct 05/06
CL−605 Flight Crew Operating Manual
PSP 605−6
OXYGEN SYSTEM (CONT'D)
Therapeutic
Provisions are made to install therapeutic oxygen ports in the passenger compartment. This
system is used for first aid, and normally supplies oxygen to four ports (forward left, aft left,
中国航空网 www.aero.cn