• 热门标签

当前位置: 主页 > 航空资料 > 飞行资料 >

时间:2010-04-23 20:45来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

IN
ASCA
ASCA
ASCA
ASCA
GF0720_113
CIRCUIT BREAKER − SYSTEM 1/1
DC ESS
BATT
AC 3
AC 4
AC 1
AC 2 DC 2
DC 1
AC ESS AV BATT
DC EMER APU BATT
ELECTRICAL
EMS CIRCUIT PROTECTION
Flight Crew Operating Manual Rev 3, Apr 25, 2005
CSP 700−5000−6
Volume 2
07−20−38
CNTL KEY
CNTL Key is used to display system control options.
NOTE
STALL WARN ADVANCE is either NORM or ADVANCE, see Chapter 10 for more information.
HUMIDIFIER
SWITCH CONTROL 1/3
STALL WARN ADVANCE
LEFT FOOTWARMER
RIGHT FOOTWARMER
SLAT/FLAP RESET OFF
SWITCH CONTROL 2/3
AC 2 CABIN PWR
AC 3 CABIN PWR
AC 4 CABIN PWR
AC 1 CABIN PWR
NORM
ON
ON
ON
ON
ON
ON
ON
SWITCH CONTROL 3/3
DC 1 CABIN PWR
DC 2 CABIN PWR 1
DC 2 CABIN PWR 2
DC 2 CABIN PWR 3
ON
ON
ON
ON
DC 2 CABIN PWR 4 ON
GF0720_114
STAT SYS BUS PREV CNTL TEST
PAGE
NEXT
PAGE
EMER
CNTL
BUS
STBY
CIRCUIT BREAKER SYSTEM
BRT
ELECTRICAL
EMS CIRCUIT PROTECTION
Rev 3, Apr 25, 2005 Flight Crew Operating Manual
CSP 700−5000−6
Volume 2
07−20−39
TEST KEY
TEST Key is used to display and initiate test options. When TEST key is selected FIRE TEST is
automatically highlighted. The TEST function can only be initiated by selecting the associated key.
After a TEST is complete, the next selection will automatically be highlighted. To terminate a TEST,
reselect
appropriate key.
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
LAMP TEST 1 OFF
FGF0720_001
STAT SYS BUS PREV CNTL TEST
PAGE
NEXT
PAGE
EMER
CNTL
BUS
STBY
CIRCUIT BREAKER SYSTEM
BRT
TEST CONTROL 2/2
RAT TEST OFF
NOTE
When a test has been initiated via the EMSCDU
and the test is either manually or automatically
terminated, there is a 2 second delay before the test sequences to the next test. Do not attempt
to force the termination of a test by trying to select another test. Allow for the EMSCDU
to cycle
to the next test before selecting the desired test.
ELECTRICAL
EMS CIRCUIT PROTECTION
Flight Crew Operating Manual Rev 3, Apr 25, 2005
CSP 700−5000−6
Volume 2
07−20−40
TEST KEY (CONT'D)
FIRE TEST
FIRE TEST:
(duration approximately 10 seconds)
Press the FIRE TEST activation button
and note the following:
Fire and smoke aural warnings are activated.
Master warning lights flash.
Fire DISCH handles lights illuminate.
L and R ENG FIRE warning message comes on.
APU FIRE warning message comes on.
MLG BAY OVHT warning message comes on.
SMOKE AVIONICS BAY warning message comes on.
SMOKE BAGGAGE warning message comes on.
SMOKE CLOSET warning message comes on.
When the FIRE TEST is complete, all warning
messages will go out, fire aural warning deactivated
master warning lights go out and
Fire DISC handles lights go out.
After 10 seconds
GF0720_118
TEST CONTROL 1/1
FIRE TEST TEST
LAMP TEST 1
STALL TEST OFF
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
TEST CONTROL 1/1
FIRE TEST TEST
LAMP TEST 1
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
STALL TEST OFF
ELECTRICAL
EMS CIRCUIT PROTECTION
Rev 3, Apr 25, 2005 Flight Crew Operating Manual
CSP 700−5000−6
Volume 2
07−20−41
TEST KEY (CONT'D)
STALL TEST
GF0720_119
TEST CONTROL 1/1
FIRE TEST OFF
LAMP TEST 1
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
STALL TEST TEST
STALL TEST (on ground only):
(duration approximately 20 seconds)
Press the STALL TEST activation button and note the following:
· Stick shaker #1 activates, followed by stick shaker #2.
· Verify that both shakers are activated and stall aural warning is activated.
· Stick pusher is activated and STALL warning message comes on.
· Stick pusher continues to operate until both control columns reach the full forward position.
After 20 seconds
GF0720_120
TEST CONTROL 1/1
FIRE TEST
LAMP TEST 1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:Bombardier_Global_000-Electrical(26)