曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

DIR BUS
ESS BUS and
BATT BUS
Bus Bar Outline
Bus powered
Bus not powered
Invalid data
ESS BUS
ESS BUS
ESS BUS
BATT BUS
BATT BUS
BATT BUS
ELECTRICAL
7-50 For Training Purposes Only
May 03
P I LOT T R A I N I N G GU I D E
EICAS Messages
MESSAGE MEANING AURAL WARNING
(IF ANY)
EMER POWER ONLY ADG is supplying the AC essential bus, and no power is
available from AC BUS 1 or 2. TRIPLE ATTENSON
AC 1 AUTOXFER Respective automatic AC bus tie function has been inhibited because of an overcurrent
AC 2 AUTOXFER condition on the respective AC bus.
AC BUS 1
Respective AC bus is unpowered.
AC BUS 2
AC ESS BUS AC essential bus is unpowered.
APU BATTERY OFF APU battery is less than 18 VDC.
APU GEN OFF APU generator is off-line with the APU running.
APU GEN OVLD Load on the APU generator exceeds 34.5 kVA.
BATTERY BUS Battery bus is unpowered.
DC BUS 1
Respective DC bus is unpowered.
DC BUS 2
DC EMER BUS DC emergency bus is unpowered.
DC ESS BUS DC essential bus is unpowered.
GEN 1 OFF
Respective generator is OFF.
GEN 2 OFF
GEN 1 OVLD
Load on respective generator exceeds 34.5 kVA.
GEN 2 OVLD
MAIN BATTERY OFF Main battery is less than 18 VDC.
AC ESS ALTN AC essential bus is powered by AC BUS 2.
AC UTIL 1 OFF
Respective AC utility bus is unpowered.
AC UTIL 2 OFF
APU BATT CHGR FAIL APU battery is not charging or APU charger has failed.
ESS TRU 1 FAIL
Respective essential transformer-rectifier unit output is less than 18 VDC.
ESS TRU 2 FAIL
MAIN BATT CHGR FAIL Main battery is not charging or main battery charger has failed.
EICAS Messages
Table 7-1


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn