After a TEST is complete, the next selection will automatically be highlighted. To terminate a TEST,
reselect
appropriate key.
TEST CONTROL 1/2
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
LAMP TEST 1 OFF
TEST CONTROL 2/2
RAT TEST OFF
GF0720_116
STAT SYS BUS PREV CNTL TEST
PAGE
NEXT
PAGE
EMER
CNTL
BUS
STBY
CIRCUIT BREAKER SYSTEM
BRT
ELECTRICAL
EMS CIRCUIT PROTECTION
Flight Crew Operating Manual REV 41, Jul 08, 2004
CSP 700−6
Volume 2
07−20−58
TEST KEY (CONT'D)
Effectivity:
· Airplanes 9002 thru 9122 not incorporating Service Bulletin:
· SB 700−24−045, AC and DC Power Distribution − Unit Change and Activation of Build 4
Electrical System.
TEST Key is used to display and initiate test options. When TEST key is selected FIRE TEST is
automatically highlighted. The TEST function can only be initiated by selecting the associated key.
After a TEST is complete, the next selection will automatically be highlighted. To terminate a TEST,
reselect
appropriate key.
TEST CONTROL 1/1
FIRE TEST
STALL TEST
AURAL WARNING TEST 1
AURAL WARNING TEST 2
LAMP TEST 2
OFF
OFF
OFF
OFF
OFF
LAMP TEST 1 OFF
GF0720_117
STAT SYS BUS PREV CNTL TEST
PAGE
NEXT
PAGE
EMER
CNTL
BUS
STBY
CIRCUIT BREAKER SYSTEM
BRT
ELECTRICAL
EMS CIRCUIT PROTECTION
REV 41, Jul 08, 2004 Flight Crew Operating Manual
CSP 700−6
Volume 2
07−20−59
TEST KEY (CONT'D)
FIRE TEST
FIRE TEST:
(duration approximately 10 seconds)
Press the FIRE TEST activation button
and note the following:
Fire and smoke aural warnings are activated.
Master warning lights flash.
Fire DISCH handles lights illuminate.
L and R ENG FIRE warning message comes on.
APU FIRE warning message comes on.
MLG BAY OVHT warning message comes on.
SMOKE AVIONICS BAY warning message comes on.
SMOKE BAGGAGE warning message comes on.
SMOKE CLOSET warning message comes on.
When the FIRE TEST is complete, all warning
messages will go out, fire aural warning deactivated
master warning lights go out and
Fire DISC handles lights go out.
After 10 seconds
GF0720_118
TEST CONTROL 1/1
FIRE TEST TEST
LAMP TEST 1
STALL TEST OFF
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
TEST CONTROL 1/1
FIRE TEST TEST
LAMP TEST 1
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
STALL TEST OFF
ELECTRICAL
EMS CIRCUIT PROTECTION
Flight Crew Operating Manual REV 41, Jul 08, 2004
CSP 700−6
Volume 2
07−20−60
TEST KEY (CONT'D)
STALL TEST
GF0720_119
TEST CONTROL 1/1
FIRE TEST OFF
LAMP TEST 1
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
STALL TEST TEST
Effectivity:
· Airplanes 9002 thru 9122 not incorporating Service Bulletin:
· SB 700−24−045, AC and DC Power Distribution − Unit Change and Activation of Build 4
Electrical System.
STALL TEST:
STALL TEST (on ground only):
(duration approximately 20 seconds)
Press the STALL TEST activation button and note the following:
· Stick shaker #1 activates, followed by stick shaker #2.
· Verify that both shakers are activated and stall aural warning is activated.
· Stick pusher is activated and STALL warning message comes on.
· Stick pusher continues to operate until both control columns reach the full forward position.
After 20 seconds
GF0720_120
TEST CONTROL 1/1
FIRE TEST
LAMP TEST 1
AURAL WARNING TEST 1 OFF
OFF
OFF
LAMP TEST 2 OFF
AURAL WARNING TEST 2
STALL TEST OFF
OFF
NOTE
For more information refer to Chapter 10, FLIGHT CONTROLS.
ELECTRICAL
EMS CIRCUIT PROTECTION
REV 41, Jul 08, 2004 Flight Crew Operating Manual
CSP 700−6
Volume 2
07−20−61
TEST KEY (CONT'D)
AURAL WARNING TEST
AURAL WARNING TEST:
(duration approximately 60 seconds)
Press the AURAL WARNING TEST
button and note the following:
After 60 seconds
After 60 seconds
NOTE:
Pressing TEST button again will terminate aural test.
 